A sandwich-type electrochemical immunosensor based on RhPt NDs/NH2-GS and Au NPs/PPy NS for quantitative detection
Fubin Pei1, Ping Wang1, Enhui Ma1
1School of Chemistry and Chemical Engineering, Shandong University of Technology, 255049 Zibo, PR China.
Abstract:
In this work, a sandwich-type electrochemical immunosensor was fabricated to quantitatively detect hepatitis B surface antigen (HBsAg). The immunosensor was based on Rh core and Pt shell nanodendrites loaded onto amino group functionalized graphene nanosheet (RhPt NDs/NH2-GS) as label and gold nanoparticles loaded onto polypyrrole nanosheet (Au NPs/PPy NS) as platform. RhPt NDs with abundant catalytic active sites because of the branched core-shell structure, RhPt NDs/NH2-GS as the label displayed high catalytic activity, amplifying the current signal of the immunosensor. Additionally, Au NPs/PPy NS enhanced the electron transfer and provided a good microenvironment to immobilize antibodies effectively, thus improving the sensitivity of the immunosensor. Based on above advantages, the immunosensor emerged a linear concentration ranging from 0.0005 to 10 ng/mL, a low detection limit of 166 fg/mL for HBsAg (S/N = 3) and good stability, selectivity, reproducibility. Furthermore, the satisfactory accuracy in analysis of actual serum samples implied the immunosensor had promising prospect in clinical analysis applications.
More Related Videos
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Types of Receptors: Cell Surface Receptors
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Effect of Hepatic Disease on Pharmacokinetics: Dose Adjustments Due to Hepatic Impairment
Hepatic Portal System
At its core, the hepatic portal vein is the result of a confluence of the superior and inferior mesenteric veins along with the splenic vein. Each of these veins has a unique role. The superior mesenteric vein is...
Classification of Titrimetric Analysis Based on Reaction Types