Non-destructive testing of industrial equipment using muon radiography
Pablo Martinez Ruiz-Del Arbol1, Pablo Gomez Garcia2, Carlos Diez Gonzalez3
1Physics Institute of Cantabria (IFCA), University of Cantabria, Santander, Spain.
Abstract:
A new application of muon radiography (MR) is presented in the context of non-destructive testing of industrial equipment. The long-term operation of industrial facilities frequently involves the deterioration of critical components such as pipes and cauldrons due to corrosion and other processes. The precise determination of the inner state of this equipment is needed to ensure the integrity of the facility. MR can be used to infer the thickness of these components through the comparison and further classification of muon observables with respect to well-known templates. A simulation example is presented where the thickness of a pipe made of steel is studied using the Point of Closest Approach method and simple Kolmogorov-Smirnov statistical tests. A precision of about 2-4 mm is obtained using a simple detector with a spatial resolution of 4 mm and exposure times of about 2 h.This article is part of the Theo Murphy meeting issue 'Cosmic-ray muography'.
Related Concept Videos
Non-destructive Tests for Concrete Strength
Leveling Equipment
Personal Protective Equipment
Microorganisms in Agriculture and Food industry
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...