Multislice computed tomography/contrast-enhanced ultrasound image fusion as a tool for evaluating unclear renal cysts
Johannes Rübenthaler1, Stephanie Wilson2, Dirk-Andre Clevert1
1Department of Clinical Radiology, Interdisciplinary Ultrasound Center, Ludwig-MaximiliansUniversity of Munich-Grosshadern Campus, Munich, Germany.
Abstract:
Ultrasonography is a generally accepted imaging technique for diagnosing and monitoring cystic renal lesions. The widely used Bosniak classification (I-IV) categorizes renal cystic lesions into five distinctive groups according to ultrasonography and computed tomography (CT) image criteria. For solid renal lesions, determination of vascularity is discriminatory for malignancy in most instances. In indeterminate cases, contrast-enhanced ultrasound (CEUS) and magnetic resonance imaging/CT-ultrasound image fusion are able to detect and characterize difficult pathologies, with superior performance to either technique alone. In contrast to multislice CT (MS-CT), ultrasound image fusion is a real-time imaging technique that can be used in combination with other cross-sectional imaging modalities. This technical note describes state-of-the-art image fusion of CEUS and MS-CT to detect and characterize unclear renal pathologies.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Self-Evaluation: Self-Enhancement and Self-Verification
Nuclear Fusion
A helium nucleus has a mass that is 0.7% less than that of four hydrogen nuclei; this lost mass is converted into energy during the fusion. This reaction produces about...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET