Background:
Airborne microbe-carrying particles in the operating-room environment during total joint replacement are a risk factor for periprosthetic joint infection. The present study focuses on a simple environmental test, based on practices used in aseptic cleanrooms, to quantify the deposition of microbe-carrying particles onto the sterile field.
Methods:
Settle plates are exposed Petri dishes. A settle plate test system and sampling plan were developed from current practices used in aseptic manufacturing. A pilot study evaluated this system in an orthopaedic operating room during 22 total knee and hip arthroplasties. The microbial deposition total (MDT), expressed in colonies/m2, is proposed as an outcome variable to report airborne sterile-field contamination as measured with settle plates. Two reference MDT levels were developed: (1) an upper limit of 450, corresponding with the ultraclean air definition of 10 colonies/m3, and (2) a target level of 100, corresponding with 1 colony/m3. These levels also correspond with widely used limits in aseptic cleanrooms and controlled environments.
Results:
High MDT standard deviations were noted. Ninety-one percent (95% confidence interval, 71.0% to 98.7%) of wound zone MDT levels were within the upper limit. Twenty-seven percent (95% confidence interval, 12.9% to 48.4%) of wound zone levels were within the target level.
Conclusions:
Settle plates are a feasible technique to test environmental levels of microbe-carrying particles on sterile fields during total joint replacement for scientific and environmental quality studies.
Clinical Relevance:
This settle plate operating-room environmental test can be used in future research to validate the presence of actual ultraclean-air conditions during periprosthetic joint infection outcome studies. Surgeons also can use this test to measure intraoperative airborne microbe-carrying-particle sterile-field contamination and compare it with ultraclean-air reference levels for environmental quality-control programs.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Microbial Growth Measurement: Direct Methods
Microbial Growth Measurement: Indirect Methods
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Method of Joints
Since plane truss members are in the same plane, each joint is subjected to a coplanar and concurrent force system. To apply the method of joints, the first step is to...
Method of Joints: Problem Solving I