Related Experiment Video
Updated: Feb 1, 2026

High-frequency Ultrasound Imaging of Mouse Cervical Lymph Nodes
Published on: July 25, 2015
Image-guided brachytherapy in cervical cancer: Experience in the Complejo Hospitalario de Navarra
Elena Villafranca1, Paola Navarrete1, Amaya Sola1
1Department of Radiation Oncology, Hospital de Navarra, Pamplona, Spain.
Purpose:
To evaluate dosimetric and clinical findings of MRI-guided HDR brachytherapy (HDR-B) for cervical carcinoma.
Material And Methods:
All patients had a CT, MRI and pelvic-paraaortic lymphadenectomy. Treatment: pelvic (+/-)para-aortic3D/IMRT radiotherapy (45 Gy), weekly cisplatin and HDR-B and pelvic node/parametrial boost 60 Gy until interstitial brachytherapy was done. Two implants: 2008-2011: 5 fractions of 6 Gy, 2011: 2016, 4 fractions of 7 Gy. MRI/TAC were done in each implant. The following were defined: GTV, CTH-HR, CTV-IR; OAR: rectum, bladder and sigmoid.
Results:
From 2007 to 2016: 57 patients. Patients: T1b2-T2a: 4p, T2b 41p, T3a: 2p; T3B 8p T4a: 2p; N0: 32p, N1 21p, no lymphadenectomy: 4p. Median follow up: 74.6 m (16-122 m), recurrence: 5p local, 6p node, 9p metastasis and 37p without recurrence.Local control 5 years: 90.1%; Ib2-IIB: 94.8%, III-IVa: 72.2%. (p:0.01). RDFS 5y was 92.5%; IB2-IIB: 93%, III: 85% (p:0.024); for pN0: 100%; pN+ iliac-paraaortic: 71.4% (p: 0.007). MFS 5y was 84.1%. Overall survival (OS) at 5y: 66.6% and the cancer specific survival (CEOS) was 74%. Univariate analysis survival: stage Ib2-II 83% vs. III-IVa 41% (p = 0.001); histology: squamous 78%, adenocarcinoma 59.7% (p: ns); lymph node: N0 85% vs. PA+P- 72%, and PA+P+ 35% (p = 0.010). In relation with: HR-CTV dose > 85 Gy, CEOS: 82.5% vs. 77%, and volume CTV-HR < 30 cc: 81.8% and >30 cc: 67%; p: ns. Acute grade 2-3 toxicity: rectal 15.7%, intestinal 15.7% and vesical 15.5%.
Conclusion:
Use of interstitial HDR-BQ guided by RM increased CTV-HR dose and local control, like EMBRACE results. Nodal boost improves RDFS and perhaps OS.
Related Concept Videos
What is an Experiment?
Thomson's e/m Experiment
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...
Controls in Experiments
Randomized Experiments
Simple randomization
Simple...
Crossover Experiments
Crossover designs are performed even with smaller sample sizes since the samples can act as their controls. These are better than simple randomized trials since patients are exposed to all the treatments.
The Stanford Prison Experiment

