Related Experiment Video
Updated: Feb 1, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
One-millimeter isotropic breast diffusion-weighted imaging: Evaluation of a superresolution strategy in terms of
Maya Delbany1, Aurélien Bustin2, Julie Poujol1
1IADI, INSERM U1254 and Université de Lorraine, Nancy, France.
Purpose:
To quantitatively evaluate a superresolution technique for 3D, one-millimeter isotropic diffusion-weighted imaging (DWI) of the whole breasts.
Methods:
Isotropic 3D DWI datasets are obtained using a combination of (i) a readout-segmented diffusion-weighted-echo-planar imaging (DW-EPI) sequence (rs-EPI), providing high in-plane resolution, and (ii) a superresolution (SR) strategy, which consists of acquiring 3 datasets with thick slices (3 mm) and 1-mm shifts in the slice direction, and combining them into a 1 × 1 × 1-mm3 dataset using a dedicated reconstruction. Two SR reconstruction schemes were investigated, based on different regularization schemes: conventional Tikhonov or Beltrami (an edge-preserving constraint). The proposed SR strategy was compared to native 1 × 1 × 1-mm3 acquisitions (i.e. with 1-mm slice thickness) in 8 healthy subjects, in terms of signal-to-noise ratio (SNR) efficiency, using a theoretical framework, Monte Carlo simulations and region-of-interest (ROI) measurements, and image sharpness metrics. Apparent diffusion coefficient (ADC) values in normal breast tissue were also compared.
Results:
The SR images resulted in an SNR gain above 3 compared to native 1 × 1 × 1-mm3 using the same acquisition duration (acquisition gain 3 and reconstruction gain >1). Beltrami-SR provided the best results in terms of SNR and image sharpness. The ADC values in normal breast measured from Beltrami-SR were preserved compared to low-resolution images (1.91 versus 1.97 ×10-3 mm2 /s, P = .1).
Conclusion:
A combination of rs-EPI and SR allows 3D, 1-mm isotropic breast DWI data to be obtained with better SNR than a native 1-mm isotropic acquisition. The proposed DWI protocol might be of interest for breast cancer monitoring/screening without injection.
Related Concept Videos
Diffusion
Diffusion
Apparent Weight
Consider a person standing on a bathroom scale inside an elevator. If the scale is accurate at rest, its reading equals the...
Apparent Weight and the Earth's Rotation
For an object on the Earth's equator, the net centripetal force that accounts for its rotation is the Earth's pull towards its center, or the weight minus the normal force that prevents it from piercing into the Earth's surface....
Facilitated Diffusion
In this process, substrates such as organic compounds and ions interact with a transporter on one side, triggering conformational changes in proteins that enable...
Behavior of Gas Molecules: Molecular Diffusion, Mean Free Path, and Effusion

