Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
Detection of urinary trace elements and pattern recognition analysis in patients with renal cell carcinoma by
Jiaxin Zheng1, Bin Chen1, Rongfu Liu1
1Department of Urology and Center of Urology, The First Affiliated Hospital of Xiamen University, Xiamen, China.
Objective:
This study aims to observe the changes and diagnostic values of urinary trace elements in patients with renal cell carcinoma (RCC).
Methods:
A total of 28 RCC patients that had been performed radical surgery for more than 3 years were included into this case-control study; meanwhile, thirty healthy volunteers without kidney diseases were set as the control group over the same period. The levels of various urinary trace elements in both groups were measured, and the results were performed the significance analysis and pattern recognition analysis using with partial least square discriminant analysis and Fisher analysis.
Results:
The significance analysis showed that compared with the control group, the case group exhibited significantly reduced levels of Mg (26.3 mg/L for the case group vs. 52.1 mg/L for the control group, P < 0.05), V (72.9 μg/L for the case group vs. 110.1 μg/L for the control group, P < 0.05), Mo (59.6 μg/L for the case group vs. 261.7 μg/L for the control group, P < 0.05), and Sn (4.5 μg/L for the case group vs. 27.3 μg/L for the control group, P < 0.05) while significantly increased Cd (25.0 μg/L for the case group vs. 15.5 μg/L for the control group, P < 0.05). The accuracy of the discriminant function established by the Fisher analysis was 91.4%.
Conclusions:
Patients with RCC exhibit differences in such urinary trace elements as Mg, V, Mo, Sn, and Cd with healthy populations, and the discriminant accuracy is high.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometry: Overview