Related Experiment Video
Updated: Feb 1, 2026

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
Re-exposure in cone beam CT of the dentomaxillofacial region: a retrospective study
Yasamin Habibi1, Edriss Habibi2, Bilal Al-Nawas1
11 Department of Oral and Maxillofacial Surgery, Plastic Surgery, University Medical Center of the Johannes Gutenberg-University Mainz , Mainz , Germany.
Methods::
In a retrospective cohort study CBCT images of 4986 patients from the patient database from the Department of Oral Radiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany were included and the rate of re-exposures was counted. Patients were stratified into those who received a scan with the small field-of-view CBCT or the large field-of-view CBCT. The effect of patient-related parameters as age and gender was implicated. As a further device-specific parameter, the statistical analysis included whether the selection of the field of view due to the device type had a significant influence on the occurrence of re-exposures. Furthermore, the rescans were analyzed with regard to their causes.
Results::
In total, CBCT images of 82 (1.6%) patients had to be repeated. Looking at the two different devices, in 42 (1.3%) patients that received a scan with the large field-of-view CBCT and in 40 (2.3%) patients that received a scan with the small field-of-view CBCT respectively needed a retake. There was no statistically significant correlation between age and gender to retakes. For the small field-of-view-size significantly more retakes were observed than for the large one. With 46% motion artifacts were the most frequent causes for a re-exposure of the patient.
Conclusions::
Gender and age did not have an impact on the occurrence of re-exposures. Patients who received a scan with the small field-of-view CBCT were significantly more often rescanned than those with the large field-of-view CBCT.
More Related Videos
08:04Cone-Enriched Cultures from the Retina of Chicken Embryos to Study Rod to Cone Cellular Interactions
Published on: March 20, 2021
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
IR Frequency Region: Fingerprint Region
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...