A combined mono- and multi-turbine approach for fault indicator synthesis and wind turbine monitoring using SCADA
Alexis Lebranchu1, Sylvie Charbonnier2, Christophe Bérenguer2
1University Grenoble Alpes, CNRS, Grenoble INP, GIPSA-lab, F-38000 Grenoble, France; Valemo S.A.S, F-33323, Bègles, France.
Abstract:
The monitoring of wind turbines using SCADA data has received lately a growing interest from the fault diagnosis community because of the very low cost of these data, which are available in number without the need for any additional sensor. Yet, these data are highly variable due to the turbine constantly changing its operating conditions and to the rapid fluctuations of the environmental conditions (wind speed and direction, air density, turbulence, …). This makes the occurrence of a fault difficult to detect. To address this problem, we propose a multi-level (turbine and farm level) strategy combining a mono- and a multi-turbine approach to create fault indicators insensitive to both operating and environmental conditions. At the turbine level, mono-turbine residuals (i.e. a difference between an actual monitored value and the predicted one) obtained with a normal behavior model expressing the causal relations between variables from the same single turbine and learnt during a normal condition period are calculated for each turbine, so as to get rid of the influence of the operating conditions. At the farm level, the residuals are then compared to a wind farm reference in a multi-turbine approach to obtain fault indicators insensitive to environmental conditions. Indicators for the objective performance evaluation are also proposed to compare wind turbine fault detection methods, which aim at evaluating the cost/benefit of the methods from a production manager's point of view. The performance of the proposed combined mono- and multi-turbine method is evaluated and compared to more classical methods proposed in the literature on a large real data set made of SCADA data recorded on a French wind farm during four years : it is shown than it can improve the fault detection performance when compared to a residual analysis limited at the turbine level only.
More Related Videos
Related Concept Videos
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Turbine-Governor Control
Indicators
Fault Types
For line-to-line faults occurring between phases B and C, the...
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Model Approaches for Pharmacokinetic Data: Compartment Models
Two primary types of compartment models are recognized: mammillary and catenary. The more...