Characterization of Proteins by Size-Exclusion Chromatography Coupled to Multi-Angle Light Scattering SEC-MALS
Published on: June 20, 2019
Size-exclusion chromatography small-angle X-ray scattering of water soluble proteins on a laboratory instrument
Saskia Bucciarelli1, Søren Roi Midtgaard2, Martin Nors Pedersen2
1Department of Drug Design and Pharmacology, University of Copenhagen, Denmark.
Abstract:
Coupling of size-exclusion chromatography with biological solution small-angle X-ray scattering (SEC-SAXS) on dedicated synchrotron beamlines enables structural analysis of challenging samples such as labile proteins and low-affinity complexes. For this reason, the approach has gained increased popularity during the past decade. Transportation of perishable samples to synchrotrons might, however, compromise the experiments, and the limited availability of synchrotron beamtime renders iterative sample optimization tedious and lengthy. Here, the successful setup of laboratory-based SEC-SAXS is described in a proof-of-concept study. It is demonstrated that sufficient quality data can be obtained on a laboratory instrument with small sample consumption, comparable to typical synchrotron SEC-SAXS demands. UV/vis measurements directly on the SAXS exposure cell ensure accurate concentration determination, crucial for direct molecular weight determination from the scattering data. The absence of radiation damage implies that the sample can be fractionated and subjected to complementary analysis available at the home institution after SEC-SAXS. Laboratory-based SEC-SAXS opens the field for analysis of biological samples at the home institution, thus increasing productivity of biostructural research. It may further ensure that synchrotron beamtime is used primarily for the most suitable and optimized samples.
More Related Videos
06:49In situ Grazing Incidence Small Angle X-ray Scattering on Roll-To-Roll Coating of Organic Solar Cells with Laboratory X-ray Instrumentation
Published on: March 2, 2021
06:26Rapid Assessment of Membrane Protein Quality by Fluorescent Size Exclusion Chromatography
Published on: January 6, 2023
Related Concept Videos
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
High-Performance Liquid Chromatography: Instrumentation
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...
Solubility Equilibria: Ionic Product of Water
The ionic product of water varies with temperature, and its value is 1.0 x 10−14 at standard experimental conditions. Per Le...
Factors Affecting Solubility
Solubility Equilibria
The...