Related Experiment Video
Updated: Feb 1, 2026

Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Conduction recovery following pacemaker implantation after transcatheter aortic valve replacement
Rachel M Kaplan1, Ajay Yadlapati1, Eric P Cantey1
1Division of Cardiology, Bluhm Cardiovascular Institute, Feinberg School of Medicine, Northwestern University, Chicago, Illinois.
Background:
Transcatheter aortic valve replacement (TAVR) is increasingly used to treat severe aortic stenosis. A frequent complication of TAVR is high-grade or complete atrioventricular (AV) block requiring a permanent pacemaker (PPM). There are little data on the long-term dependency on pacing after TAVR. The objective of this study was to determine the proportion of patients receiving a PPM for high-grade or complete AV block after TAVR who remain dependent on the PPM in follow-up and to determine any risk factors for, particularly the effect of postballoon dilation (PBD) on, pacemaker dependency.
Methods:
Of 594 consecutive patients without prior PPM undergoing TAVR (81.9% balloon-expandable, 18.1% self-expandable valve), 67 (13.1%) received a PPM after TAVR. PPM dependency was defined as AV block with a ventricular escape rate of ≤ 40 beats/min. Patient and procedural characteristics were examined according to PPM dependency status.
Results:
Of the 67 patients who received a PPM within 10 days after TAVR, 27/67 (40.3%) were dependent at first follow-up and only 9/41 (21.9%) at 1 year. PPM dependency was more common after a self-expanding valve (76.9% vs 31.5%, P < 0.01), in those who underwent PBD (66.7% vs 24.4%, P < 0.01), and in patients in persistent complete AV block at PPM implantation (62.5% vs 7.4%, P < 0.01).
Conclusions:
Fewer than half of patients who receive a new PPM following TAVR are pacemaker dependent at early follow-up (< 30 days). The use of self-expanding valves and PBD are associated with a markedly increased risk of PPM dependency.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduct Disorder
Electrical Conductivity
In a practical conductor, an applied electric field may be sustained, causing a flow of electrons, which produce a current. The differential form of the current, the current density, is related to the electric field.
More generally, it is related to the force per unit charge, which involves the...
Resistance and Conductance
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...

