Background:
Two-implant overdentures (2-IODs) is an expected treatment option to improve the masticatory performance (MP) of edentulous individuals.
Purpose:
The purpose of the current study was to compare MPs between immediately loaded and conventionally loaded mandibular 2-IODs retained by magnet attachments.
Materials And Methods:
Nineteen participants with edentulous mandibles were randomly assigned to an immediately loaded group or a conventionally loaded group. Each participant received two implants. The immediate group was loaded on the same day as implant insertion, whereas the conventional group was loaded 3 months after implant insertion. Both MP, measured by a color-changeable chewing gum and a gummy jelly, and maximum occlusal force were assessed at baseline and at 1, 3, 6, 12, 24, and 36 months after implant insertion.
Results:
A significantly higher MP, measured by gummy jelly, was observed at the 6-month time-point in the immediate group (P = .034). No significant differences in MP, measured by chewing gum, or maximum occlusal force were observed between the two groups at any time-point.
Conclusions:
Within the limitations of the present study, immediate loading of 2-IODs could improve MP at an earlier time-point than conventional loading of 2-IODs.
Related Concept Videos
Impact Loading
In cases of elastic deformation,...
Distributed Loads
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
Eccentric Loading
Load along a Single Axis
Consider a beam of length L subjected to a varying load, which is a combination of parabolic and trapezoidal load distribution along the x-axis. In this case, it is essential to determine the resultant loads, their locations, and...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...