Related Experiment Video
Updated: Jan 31, 2026

Fabrication of Carbon-Based Ionic Electromechanically Active Soft Actuators
Published on: April 25, 2020
A Hybrid Control with PID⁻Improved Sliding Mode for Flat-Top of Missile Electromechanical Actuator Systems
Man Zhou1,2, Dapeng Mao3, Mingyue Zhang4
1Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China. zhouman0741@163.com.
Abstract:
Electromechanical actuator (EMA) systems are widely employed in missiles. Due to the influence of the nonlinearities, there is a flat-top of about 64 ms when tracking the small-angle sinusoidal signals, which significantly reduces the performance of the EMA system and even causes the missile trajectory to oscillate. Aiming to solve these problems, this paper presents a hybrid control for flat-top situations. In contrast to the traditional PID or sliding mode controllers that missiles usually use, this paper utilizes improved sliding mode control based on a novel reaching law to eliminate the flat-top during the steering of the input signal, and utilizes the PID control to replace discontinuous control and improve the performance of EMA system. In addition, boundary layer and switching function are employed to solve the high-frequency chattering problem caused by traditional sliding mode control. Experiments indicate that the hybrid control can evidently reduce the flat-top time from 64 ms to 12 ms and eliminate the trajectory limit cycle oscillation. Compared with PID controllers, the proposed controller provides better performance-less chattering, less flat-top, higher precision, and no oscillation.
Related Concept Videos
PID Controller
Control Systems
At the heart...
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
Feedback control systems
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Transfer Function in Control Systems
To derive the transfer function, consider a general nth-order linear time-invariant...

