Related Experiment Video
Updated: Jan 31, 2026

08:18
Engineered Vascularized Muscle Flap
Published on: January 11, 2016
8.7K
Muscle-Splitting Augmentation-Mastopexy: Implant Protection With an Inferior Dermoglandular Flap.
Rubem Lang Stümpfle, Pedro Salomão Piccinini1, Lucas Figueras Pereira-Lima2
1Hospital São Lucas, Pontifical Catholic University of Rio Grande do Sul.
Annals of Plastic Surgery
|December 19, 2018
Summary
This study presents a novel augmentation-mastopexy technique using a muscle-splitting pocket and inferior flap, significantly reducing revision rates and complications for improved breast shape and patient satisfaction.
Area of Science:
- Plastic Surgery
- Reconstructive Surgery
- Aesthetic Surgery
Background:
- Simultaneous augmentation-mastopexy offers high patient and surgeon satisfaction but faces challenges with revision rates up to 25%.
- Common reasons for reoperation include recurrent ptosis and poor breast shape.
- Significant complications involve implant exposure, infection, and wound breakdown, potentially linked to implant size and closure tension.
Purpose of the Study:
- To describe and evaluate a novel augmentation-mastopexy technique combining a muscle-splitting pocket with an inferior flap.
- To assess the safety and efficacy of this technique in reducing complications and revision rates.
Main Methods:
- A retrospective chart review of 118 patients (236 breasts) undergoing augmentation-mastopexy between January 2015 and December 2017.
- The technique involved round, textured silicone gel implants placed in a muscle-splitting pocket, augmented by an inferior de-epithelialized dermoglandular flap.
- Data collected included patient demographics, operative time, implant size, follow-up duration, and complication rates.
Main Results:
- No cases of implant extrusion, nipple-areola complex ischemia, or surgical site infection were reported.
- One patient required revision for implant malposition, and two experienced postoperative hematomas.
- The mean follow-up was 13 months, with a low overall complication and revision rate.
Conclusions:
- The described augmentation-mastopexy technique effectively combines established methods for improved aesthetic outcomes and implant safety.
- The muscle-splitting pocket and inferior flap provide implant protection against wound breakdown and contribute to high patient satisfaction.
- This approach demonstrates a low revision rate and minimal complications, addressing key challenges in simultaneous augmentation-mastopexy.
Related Concept Videos
¹H NMR: Complex Splitting
1.9K
A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
1.9K
Protection of Alcohols
8.1K
This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.1K
Zones of Protection
794
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
794
Radial System Protection
443
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
443
Protecting Self-Esteem
210
Self-esteem, a central component of psychological well-being, is actively maintained through various cognitive and behavioral strategies. Individuals employ specific mechanisms to preserve a positive self-concept and mitigate threats to their self-worth, particularly in contexts involving social evaluation or personal feedback. Four primary techniques are commonly used to sustain self-esteem.Manipulating AppraisalsOne prominent strategy involves manipulating appraisals from others. Individuals...
210
Line Protection with Impedance Relays
454
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
454

