Related Experiment Video
Updated: Jan 31, 2026

Myocardial Infarction and Functional Outcome Assessment in Pigs
Published on: April 25, 2014
Non-contrast myocardial infarct scar assessment using a hybrid native T1 and magnetization transfer imaging sequence
Chong Duan1, Yanjie Zhu1,2, Jihye Jang1,3
1Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts.
Purpose:
To develop a gadolinium-free cardiac MR technique that simultaneously exploits native T1 and magnetization transfer (MT) contrast for the imaging of myocardial infarction.
Methods:
A novel hybrid T one and magnetization transfer (HYTOM) method was developed based on the modified look-locker inversion recovery (MOLLI) sequence, with a train of MT-prep pulses placed before the balanced SSFP (bSSFP) readout pulses. Numerical simulations, based on Bloch-McConnell equations, were performed to investigate the effects of MT induced by (1) the bSSFP readout pulses, and (2) the MT-prep pulses, on the measured, "apparent," native T1 values. The HYTOM method was then tested on 8 healthy adult subjects, 6 patients, and a swine with prior myocardial infarction (MI). The resulting imaging contrast between normal myocardium and infarcted tissues was compared with that of MOLLI. Late gadolinium enhancement (LGE) images were also obtained for infarct assessment in patients and swine.
Results:
Numerical simulation and in vivo studies in healthy volunteers demonstrated that MT effects, resulting from on-resonance bSSFP excitation pulses and off-resonance MT-prep pulses, reduce the measured T1 in both MOLLI and HTYOM. In vivo studies in patients and swine showed that the HYTOM sequence can identify locations of MI, as seen on LGE. Furthermore, the HYTOM method yields higher myocardium-to-scar contrast than MOLLI (contrast-to-noise ratio: 7.33 ± 1.67 vs. 3.77 ± 0.66, P < 0.01).
Conclusion:
The proposed HYTOM method simultaneously exploits native T1 and MT contrast and significantly boosts the imaging contrast for myocardial infarction.
Related Concept Videos
Magnetic Resonance Imaging
Hybrid Zones
Hybridization of Atomic Orbitals I
Imaging Studies IV: Magnetic Resonance Imaging
Hybridization of Atomic Orbitals II
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...