Response Surface Methodology of Pre-Concentration of Chorophenols from Seawater Samples by Molecularly Imprinted Stir
1Department of Marine Chemistry, Faculty of Marine Science, Chabahar Maritime University, Chabahar, Iran.
Abstract:
A novel molecularly imprinted polymer coated stir bar was prepared using 2-chlorophenol (2-CP) as template molecule and used for selective extraction of phenolic compounds including chlorophenols (CPs) directly from seawater samples. Various parameters affecting extraction have been evaluated using one variable-at-a-time and Box-Behnken design. A three-level Box-Behnken experimental design by six factors, which combined the response surface methodology, was used to optimize the selective extraction of the CPs. Six independent variables, including the absorption and desorption times (ranging from 15 to 25 min), stirring speed (ranging from 550 to 650 rpm), pH of solution (ranging from 4.0 to 6.0), amount of NaCl (ranging from 0.30 to 0.40 mol/L) and temperature of extraction process (ranging from 40 to 50°C) were coded as A, B, C, D, E and F at three various levels (-1, 0 and 1). Under the optimum conditions, the detection limits calculated were 0.17, 0.33 and 0.38 μg/L, respectively, for 2-CP, 2,4-dichlorophenol and 2,4,6-trichlorophenol. The linear ranges of method were 1.0-100.0 μg/L for all CPs studied. This method was employed for the direct extraction and determination of three CPs in seawater samples.
More Related Videos
09:12Optimization of Processing of Tiebangchui with Highland Barley Wine Based on the Box-Behnken Design Combined with the Entropy Method
Published on: May 19, 2023
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Response Surface Methodology
The process of RSM involves several key steps:
Imprinting
Genomic Imprinting and Inheritance
The expression of some genes depends on which parent passed the gene to the offspring, through a phenomenon known as...
Bar Graph
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Design Example: Frog Muscle Response