Related Experiment Video
Updated: Jan 31, 2026

Robot-assisted Partial Splenectomy
Published on: January 2, 2026
Robot-assisted tremor control for performance enhancement of retinal microsurgeons
Marina Roizenblatt1,2,3, Alex Treiger Grupenmacher2, Rubens Belfort Junior2,3
1Department of Ophthalmology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA maroizenb@gmail.com.
Abstract:
Pars plana vitrectomy is a challenging, minimally invasive microsurgical procedure due to its intrinsic manoeuvres and physiological limits that constrain human capability. An important human limitation is physiological hand tremor, which can significantly increase the risk of iatrogenic retinal damage resulting from unintentional manoeuvres that affect anatomical and functional surgical outcomes. The limitations imposed by normal physiological tremor are more evident and challenging during 'micron-scale' manoeuvres such as epiretinal membrane and internal limiting membrane peeling, and delicate procedures requiring coordinated bimanual surgery such as tractional retinal detachment repair. Therefore, over the previous three decades, attention has turned to robot-assisted surgical devices to overcome these challenges. Several systems have been developed to improve microsurgical accuracy by cancelling hand tremor and facilitating faster, safer and more effective microsurgeries. By markedly reducing tremor, microsurgical precision is improved to a level beyond present human capabilities. In conclusion, robotics offers potential advantages over free-hand microsurgery as it is currently performed during ophthalmic surgery and opens the door to a new class of revolutionary microsurgical modalities. The skills transfer that is beyond human capabilities to robotic technology is a logical next step in microsurgical evolution.
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Bioavailability Enhancement: Drug Solubility Enhancement
Bioavailability Enhancement: Drug Permeability Enhancement
Bioavailability Enhancement: Drug Stability Enhancement and GI Retention
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...
Combinatorial Gene Control
The expression of more than 30,000 genes is controlled by approximately 2000-3000 transcription factors. This is possible because a single transcription factor can recognize more than one regulatory sequence. The specificity in gene...

