Related Experiment Video
Updated: Jan 31, 2026

Optimizing Sample Preparation for Cryogenic Electron Microscopy
Published on: April 11, 2025
The Laplace Project: An integrated suite for preparing and transferring atom probe samples under cryogenic and UHV
Leigh T Stephenson1, Agnieszka Szczepaniak1,2, Isabelle Mouton1
1Max-Planck-Institut für Eisenforschung GmbH, Max-Planck-Straße 1, 40237 Düsseldorf, Germany.
Abstract:
We present sample transfer instrumentation and integrated protocols for the preparation and atom probe characterization of environmentally-sensitive materials. Ultra-high vacuum cryogenic suitcases allow specimen transfer between preparation, processing and several imaging platforms without exposure to atmospheric contamination. For expedient transfers, we installed a fast-docking station equipped with a cryogenic pump upon three systems; two atom probes, a scanning electron microscope / Xe-plasma focused ion beam and a N2-atmosphere glovebox. We also installed a plasma FIB with a solid-state cooling stage to reduce beam damage and contamination, through reducing chemical activity and with the cryogenic components as passive cryogenic traps. We demonstrate the efficacy of the new laboratory protocols by the successful preparation and transfer of two highly contamination- and temperature-sensitive samples-water and ice. Analysing pure magnesium atom probe data, we show that surface oxidation can be effectively suppressed using an entirely cryogenic protocol (during specimen preparation and during transfer). Starting with the cryogenically-cooled plasma FIB, we also prepared and transferred frozen ice samples while avoiding significant melting or sublimation, suggesting that we may be able to measure the nanostructure of other normally-liquid or soft materials. Isolated cryogenic protocols within the N2 glove box demonstrate the absence of ice condensation suggesting that environmental control can commence from fabrication until atom probe analysis.
More Related Videos
06:00Biological Samples Preparation for Speciation at Cryogenic Temperature using High-Resolution X-Ray Absorption Spectroscopy
Published on: May 27, 2022
06:42Cryogenic Sample Loading into a Magic Angle Spinning Nuclear Magnetic Resonance Spectrometer that Preserves Cellular Viability
Published on: September 1, 2020
Related Concept Videos
Poisson's And Laplace's Equation
Definition of Laplace Transform
Atomic Mass
Fischer Projections
Atomic Structure
Preparation of Samples for Electron Microscopy