Related Experiment Video
Updated: Jan 31, 2026

Optimization of the Cuff Technique for Murine Heart Transplantation
Published on: June 26, 2020
Recurrent Bacteremia After Heart Transplantation Due to Abandoned Lead Fragment in an Anonymous Vein-A Case Report
H Burger1, T Ziegelhoeffer1, M Schoenburg1
1Department of Cardiac Surgery, Kerckhoff Klinik, Bad Nauheim, Germany.
Insights
Abandoned implantable cardioverter-defibrillator (ICD) leads after heart transplantation (HTx) can cause serious infections. Complete removal of all foreign material during HTx is crucial to prevent complications like recurrent bacteremia.
Area of Science:
- Cardiology
- Infectious Diseases
- Medical Device Technology
Background:
- Heart transplantation (HTx) is the optimal treatment for end-stage heart failure.
- Many HTx candidates have implanted cardioverter-defibrillators (ICDs) for heart failure and sudden cardiac death prevention.
- Complete removal of cardiac-implanted electronic devices is standard during HTx.
Observation:
- A patient developed recurrent staphylococcal bacteremia after HTx.
- Incomplete removal of an ICD lead during the initial HTx procedure was identified as the source.
- Positron emission tomography-computed tomography (PET-CT) successfully located the infected, abandoned lead fragment.
Findings:
- A minimally invasive percutaneous extraction of the abandoned ICD lead fragment was performed.
- The patient recovered fully with no further complications post-extraction.
- This case demonstrates a rare but serious complication of retained ICD material.
Implications:
- Highlights the critical importance of meticulous removal of all foreign materials during HTx.
- Emphasizes the diagnostic utility of PET-CT for identifying challenging infection sources.
- Supports the use of minimally invasive techniques for foreign body extraction in post-transplant patients.
Abstract:
Heart transplantation (HTx) represents the "gold standard" in end-stage heart failure therapy. Due to their severe heart failure and for prevention of sudden cardiac death, the majority of patients presenting for HTx will have a history of an implanted cardioverter-defibrillator (ICD). Usually, within the scope of HTx, all cardiac-implanted electronic device components are removed. In rare cases these efforts fail and some material remains. The abandoned lead fragments can cause serious complications. The case presented herein involves a patient with recurrent bacteremia after successful HTx originating from an abandoned and infected lead fragment. In 2016, a 64-year-old man received a donor heart transplant due to end-stage heart failure. Unfortunately, during the procedure, not all components of an ICD implanted in 2007 could be removed. An initially event-free period was followed by recurrent fever attacks and staphylococcal bacteremia was diagnosed. After an extensive search, the source of the bacteremia was identified by positron emission tomography-computed tomography (PET-CT), and percutaneous extraction of the abandoned and infected ICD lead fragment was scheduled. The fragment was extracted using a minimally invasive approach via percutaneous femoral vein access. The patient was discharged 3 days later, with no further complications. This case highlights the need for conscientious and complete removal of foreign material in the HTx setting. Difficult-to-diagnose sources of infection could be reliably identified by PET-CT. When required, extraction of the foreign body should be done using a minimally invasive approach.
Related Concept Videos
Habitat Fragmentation
Anatomy of the Heart
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Data Reporting and Recording
Phase-lead and Phase-lag Controllers
Types of Reports I: Hands-off Report
Following are the key components and categories of hand-off reports:
Purpose and Process:

