Delirium detection using relative delta power based on 1-minute single-channel EEG: a multicentre study

T Numan1, M van den Boogaard2, A M Kamper3

  • 1Department of Intensive Care Medicine and Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.

Summary

A brief EEG recording can help detect delirium in older patients after surgery. This method shows promise for routine, objective delirium detection using slower brain wave frequencies.

Related Concept Videos

The Delta-to-Delta Circuit01:17

The Delta-to-Delta Circuit

In a delta-delta configuration, the source and the load are connected in a delta manner, forming a closed loop that divides the network into three distinct phases. This configuration makes the phase voltages identical to line voltages. Assuming the sources are in positive sequence, the phase voltages can be expressed directly without having a neutral wire.
1.1K
Acid and Bases: Ka, pKa, and Relative Strengths02:35

Acid and Bases: Ka, pKa, and Relative Strengths

This lesson delves into a critical aspect of the relative strengths of acids and bases. The strength of an acid is evaluated by the acid dissociation into its conjugate base and a hydronium ion in water. The complete dissociation of a strong acid is confirmed with a very high concentration of hydronium ions. As a result, an incomplete dissociation process affirms a weak acid. Therefore, the equilibrium is in the forward direction for strong acids and backward for weak acids in these reactions.
33.2K
Relative Strengths of Conjugate Acid-Base Pairs02:29

Relative Strengths of Conjugate Acid-Base Pairs

Brønsted-Lowry acid-base chemistry is the transfer of protons; thus, logic suggests a relation between the relative strengths of conjugate acid-base pairs. The strength of an acid or base is quantified in its ionization constant, Ka or Kb, which represents the extent of the acid or base ionization reaction. For the conjugate acid-base pair HA / A−, the ionization equilibrium equations and ionization constant expressions are
52.4K
The Y-to-Delta Circuit01:19

The Y-to-Delta Circuit

A balanced wye-to-delta circuit comprises balanced Y-connected voltage sources and delta-connected loads with no neutral line connection.
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
710
The Delta-to-Y Circuit01:16

The Delta-to-Y Circuit

In the delta-wye circuit, the source is delta-connected, while the load is in a wye configuration. This means that the phase voltage of the delta-connected source is equal to the line voltage of the wye-connected load. The connection between two-line currents originates from the delta-connected source. The phase difference in the balanced system allows for calculating one line current given the other, utilizing the positive sequence of phases. In the delta-wye system, the phase currents in the...
867
Power Distribution in Three-phase and Single Phase Circuits01:17

Power Distribution in Three-phase and Single Phase Circuits

Power distribution within electrical circuits is a foundational aspect of residential and industrial energy systems. While single-phase power is common in residential settings, three-phase power is the standard for industrial environments with heavy machinery. Each system is different and has advantages, and it's crucial to understand the underlying principles of power distribution and material efficiency.
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...
637