Related Experiment Video
Updated: Jan 31, 2026

Hydra, a Computer-Based Platform for Aiding Clinicians in Cardiovascular Analysis and Diagnosis
Published on: September 26, 2018
Smart platform for the analysis of cupula deformation caused by otoconia presence within SCCs
Radun Vulović1, Milica Nikolić2, Nenad Filipović2
1a Bioengineering Research and Development Center - BioIRC , Kragujevac , Serbia.
Abstract:
In this paper, we first briefly describe the mechanical model of cupula deformation with the appropriate analytical solution. Then, we present the numerical solution of the same problem and compare it with the analytical one. Besides, we provide another numerical solution based on the Finite Element Method procedure, in an effort to encompass a more realistic approach to the problem such as considering the real geometry of the SCCs and the obstruction of the fluid flow during head movement due to the presence of otoconia. As a result, we obtain fifty solutions for a head rotation angle in a range from 0° to 120°, taking into account that such a manoeuvre lasts exactly 3 seconds. In the end, we present a mobile client-server application for visualising the finite element solutions in a way that is convenient for the clinical practice.
Related Concept Videos
Plastic Deformations
Plastic Deformations
Temperature Dependent Deformation
Deformations in a Symmetric Member in Bending
When the member is segmented into tiny cubic elements, it is observed that the primary stress...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Deformation in a Circular Shaft