Related Experiment Video
Updated: Jan 31, 2026

Magnetically-Assisted Remote Controlled Microcatheter Tip Deflection under Magnetic Resonance Imaging
Published on: April 4, 2013
[Research and application of magnetic resonance coordinate transformation method for brain control technology of carp
Yong Peng1, Tingting Wang2, Zhanqiu Wang3
1Department of Biomedical Engineering, College of Electrical Engineering, Yanshan University, Qinhuangdao, Hebei 066004, P.R.China;Key Laboratory of National Defense of Mechanical Structure And Material Science Under Extreme Conditions, Yanshan University, Qinhuangdao, Hebei 066004, P.R.China.PY81@sina.com.
Abstract:
To solve the problem of precise positioning of carp brain tissue coordinates, it is proposed in this paper for a method for transforming the coordinates of magnetic resonance imaging of carp brain tissue into the coordinates of electrode implantation using a brain stereotaxic apparatus. In this study, the 3.0T magnetic resonance imaging instrument was used to scan the carp brain. We independently established the three-dimensional positioning coordinate system of the brain, the three-dimensional coordinate assistance system of skull surface and the three-dimensional coordinate assistance system in brain tissue. After two coordinate transformations, the magnetic resonance image coordinates of the brain electrodes implantation sites were converted into the three-dimensional stereotactic coordinate system to guide the electrodes implantation. The experimental groups were divided into two groups, A and B. Group A was the group of magnetic resonance imaging apparatus combining with the brain stereotaxic apparatus, and group B was the group of brain atlas combining with the brain stereotaxic apparatus. Each group had 20 tails of carps ( n = 20). This two methods were used to implant the electrodes into the cerebellar motor area. The underwater experiments of the carp robots were carried out to test the two methods. The results showed that the accuracy of the implanted electrodes were 90% in group A and 60% in group B. The success rate of group A was significantly higher than that of group B ( P < 0.05). Therefore, the new method in this paper can accurately determine the coordinates of carp brain tissue.
More Related Videos
10:21Metabolic Support of Excised, Living Brain Tissues During Magnetic Resonance Microscopy Acquisition
Published on: October 18, 2017
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
Related Concept Videos
Vector Transformation in Rotating Coordinate Systems
Magnetic Resonance Imaging
Atomic Nuclei: Magnetic Resonance
Control Systems: Applications
In modern vehicles, control systems manage various functions to enhance performance and safety. The steering wheel and accelerator are primary inputs in a car's control system. The...
Area Computation by the Alternative Coordinate Method
Coordination Number and Geometry