External Quality Assessment of Glycated Hemoglobin in Iran: Comparison of Five Different Commercial Methods with Two
Fereshteh Atabi1, Reza Mohammadi1,2
1Department of Biochemistry and Pharmacology, Islamic Azad University, Tehran Medical Sciences Branch, Tehran, Iran.
Background:
Glycated hemoglobin (HbA1c) measuring has a critical role in the monitoring and diagnosis of diabetes. So, the analytical performance of its measuring method must be acceptable. Clinical laboratories should continuously monitor the performance of their commercial methods, both by using proper internal quality control (IQC) and by participating in external quality assessment schemes (EQAS).
Methods:
In January and August 2016, two different freshly prepared commutable patient QC samples were sent to over 1000 laboratories, but 682 and 925 different laboratories which were used five common commercial methods for measuring HbA1c, included in this study during 23th and 24th runs of the external quality assessment program (EQAP), respectively. Target values for total group and also for peer groups were calculated. The performance of each method and laboratory were determined according to two different allowable total errors (TEa), including ±6% and ±20%, which are suggested by the National Glycohemoglobin Standardization Program (NGSP) and Reference Health Laboratory of Iran, respectively.
Results:
Considering TEa of ±20% in evaluating HbA1c commercial methods and laboratory performances, pass rates ranged from 97% to 98% during EQAP-23 and EQAP-24, respectively. But when this evaluation was performed according to TEa of ±6%, pass rates decreased significantly to 60% and 62%, respectively.
Conclusions:
Using improper analytical goals has led to misinterpretation of EQA results. In order to maintain the clinical usefulness of HbA1c results, we need to reduce TEa of ±20% to ±6% and improve HbA1c measuring method performance. Although, with TEa of ±6% our pass rates are not so bad.
Related Concept Videos
Hemoglobin
When all four heme groups are bound to oxygen, the resulting molecule is called oxyhemoglobin. As a result, arterial blood...
Fundamental Attribution Error
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Work Done on a System by External Force
In the presence of a non-conservative opposing force, like friction, some part of the work done...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...