Related Experiment Video
Updated: Jan 31, 2026

Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Cloud-Point Extraction Combined with Thermal Degradation for Nanoplastic Analysis Using Pyrolysis Gas
Xiao-Xia Zhou1,2, Li-Teng Hao2, Huang-Ying-Zi Wang1
1Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education, Institute of Environmental Research at Greater Bay , Guangzhou University , Guangzhou 510006 , China.
Abstract:
The contamination of micro- and nanoplastics in marine systems and freshwater is a global issue. Determination of micro- and nanoplastics in the aqueous environment is of high priority to fully assess the risk that plastic particles will pose. Although microplastics have been detected in a variety of aquatic ecosystems, the analysis of nanoplastics remains an unsolved challenge. Herein, for the first time, a Triton X-45 (TX-45)-based cloud-point extraction (CPE) was proposed to preconcentrate trace nanoplastics in environmental waters. Under the optimum extraction conditions, an enrichment factor of 500 was obtained for two types of nanoplastics with different compositions, polystyrene (PS) and poly(methyl methacrylate) (PMMA), without disturbing their original morphology and sizes. Additionally, following thermal treatment at 190 °C for 3 h, the CPE-obtained extract could be submitted to pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) analysis for mass quantification of nanoplastics. Taking 66.2 nm PS nanoplastics and 86.2 nm PMMA nanoplastics as examples, the proposed method showed excellent reproducibility, and high sensitivity with respective detection limits of 11.5 and 2.5 fM. Feasibility of the proposed approach was verified by application of the optimized procedure to four real water samples. Recoveries of 84.6-96.6% at a spiked level of 88.6 fM for PS nanoplastics and 76.5-96.6% at a spiked level of 50.4 fM for PMMA nanoplastics were obtained. Consequently, this work provides an efficient approach for nanoplastic analysis in environmental waters.
More Related Videos
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...