Related Experiment Video
Updated: Jan 31, 2026

Minimally Invasive Endoscopic Intracerebral Hemorrhage Evacuation
Published on: October 15, 2021
Biopsy During Minimally Invasive Intracerebral Hemorrhage Clot Evacuation
Adam C Lieber1, Ian T McNeill1, Jacopo Scaggiante1
1Department of Neurosurgery, Mount Sinai Hospital, New York, New York, USA.
Background:
The safety and efficacy of brain parenchyma biopsy during minimally invasive (MIS) intracerebral hemorrhage (ICH) clot evacuation has not been previously reported. The objective of this study was to establish the safety and diagnostic efficacy of brain biopsy during MIS ICH clot evacuation and to validate the modified Boston criteria as a predictor of cerebral amyloid angiopathy (CAA) in this cohort.
Methods:
From October 2016 to March 2018, superficial and perihematomal biopsies were collected for 40 patients undergoing MIS ICH clot evacuation and analyzed by the pathology department to assess for various ICH etiologies. Additionally, the admission magnetic resonance imaging or computed tomography scan of each patient was analyzed and evaluated for the likelihood of a CAA etiology based on the modified Boston criteria. Student t test was used to analyze intergroup differences in continuous variables, and a 2-tailed Fisher exact test was used to determine intergroup differences of categorical variables, with significance set at P < 0.05.
Results:
Two of the 40 patients (5%) experienced postoperative rebleed. Four of the 40 patients (10%) had evidence of CAA on biopsy. Patients with CAA on biopsy were older (P = 0.005) and had a higher prevalence of parietal lobe (P = 0.02) and occipital lobe (P = 0.001) hemorrhage. The modified Boston criteria had a sensitivity of 100% (95% confidence interval [CI], 39.6%-100%) and a specificity of 72.2% (95% CI, 54.6%-84.2%) for predicting CAA on biopsy.
Conclusions:
Brain biopsy in MIS ICH clot evacuation is safe and allows for the diagnosis of various ICH etiologies.
Related Concept Videos
Clot Retraction and Fibrinolysis
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Inflammation
Threats to Biodiversity
Homologous Recombination

