Related Experiment Video
Updated: Jan 31, 2026

Author Spotlight: Assessing the Feasibility of Using Amplitude-Integrated EEG During Neonatal Transport
Published on: June 21, 2024
Noise Exposure on Mixed Grain and Livestock Farms in Western Australia
Ryan Mead-Hunter1, Linda A Selvey2, Krassi B Rumchev1
1Occupation, Environment and Safety, School of Public Health, Curtin University, Perth, Western Australia, Australia.
Abstract:
Noise presents an ongoing occupational health and safety issue, which despite numerous studies still presents a significant risk in agriculture with high exposures prevalent. In this study, we measured noise exposures associated with significant activities on 42 mixed grain and livestock farms in Western Australia. Employing a mixture of personal noise measurements using dosimeters, noise measurements using sound level meters, and a validated survey, we identified that 32% of farm workers were exposed to noise levels above the LAeq,8h 85 dB(A) limit, before considering extended shifts. We also noted that extended shift lengths, of up to 16 h in some cases, were possible. In addition, we found that 37% of workers were exposed to noise peak of 140 dB(C) or greater. It was further noted that hearing protection is not typically worn for the duration of an activity and is only for a small number of tasks. However we did find some evidence that farmers had begun to implement some form of noise management practice, usually in the form of buying quieter equipment or separating noisy tasks from quiet tasks. Improved education for farmer and farm workers in terms of the risks posed by noise, identifying noisy tasks, is recommended, as well as a programme to encourage better and consistent use of hearing protection.
Related Concept Videos
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
Mixing Concrete
Mixing Time
Ready Mixed Concrete
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Adrenergic Agonists: Mixed-Action Agents
Ephedrine and pseudoephedrine lack a catecholamine group, making them less susceptible to degradation by metabolic enzymes. They have increased oral bioavailability and lipophilicity, resulting in a longer duration of action. Their response is reduced by...

