Related Experiment Video
Updated: Jan 31, 2026

Imaging Membrane Potential with Two Types of Genetically Encoded Fluorescent Voltage Sensors
Published on: February 4, 2016
Optical Chemical Sensor Using Intensity Ratiometric Fluorescence Signals for Fast and Reliable pH Determination
Christian G Frankær1,2, Kishwar J Hussain2, Tommy C Dörge1
1Nano-Science Center and Department of Chemistry , University of Copenhagen , Universitetsparken 5 , 2100 Copenhagen Ø, Denmark.
Abstract:
Optical pH sensors enable noninvasive monitoring of pH, yet in pure sensing terms, the potentiometric method of measuring pH is still vastly superior. Here, we report a full spectrometer-based optical pH sensor system consisting of sensor chemistry, hardware, and software that for the first time is capable of challenging the performance of an electrode-based pH meter in specific applications such as biopharmaceutical process monitoring and in single-use bioproduction. A highly photostable triangulenium fluorophore emitting at 590 nm was immobilized in an organically modified silicon matrix that allows for fast time-response by rapid diffusion of water in and out of the resulting composite polymer deposited on a polycarbonate substrate. Fluctuations from the fiber optical sensor hardware have been reduced by including a highly photostable terrylene-based reference dye emitting at 660 nm, thus enabling intensity-based ratiometric readouts. The dyes were excited by 505 nm light from a light emitting diode. The sensor was operational within a pH range of 4.6-7.6, and was characterized and demonstrated to have properties that are comparable to those of commercial pH electrodes considering time-response ( t90 < 90 s), precision (0.03 pH-units), and drift.
Related Concept Videos
Experimental Determination of Chemical Formula
Chemical Signaling in the Endocrine System
Lipid-soluble hormones, such as steroid hormones, demonstrate an intracellular action. These hormones traverse cell membranes due to their lipid nature. Once inside the target cell, they...
Reliability and Validity
Chemical Stoichiometry and Gases: Using Ideal Gas Law to Determine Moles
Determining Order of Reaction
Rate-Determining Steps
In a multistep reaction mechanism, one of the elementary steps progresses significantly slower than the others. This slowest step is called the rate-limiting step (or rate-determining step). A reaction cannot proceed faster than its slowest step, and hence, the rate-determining step limits the overall reaction rate.
The concept of rate-determining step can be understood from the analogy of a 4-lane freeway with a short-stretch of traffic-bottleneck caused due to...