COMPARISON OF ALLIGATOR SNAPPING TURTLE ( MACROCHELYS TEMMINCKII) PLASMA BIOCHEMICAL PROFILES FROM TWO CLINICAL
Abstract:
The interpretation of plasma biochemical profiles can be confounded by the methodologies by which samples are analyzed. The goal of this study was to compare agreement between two biochemical analyzers for plasma samples from alligator snapping turtles ( Macrochelys temminckii). Blood was obtained from the dorsal coccygeal vein of captive-reared, juvenile turtles ( n = 34), stored in lithium heparin tubes, and centrifuged to separate plasma from whole blood. Plasma samples were stored at 5°C prior to and in between analyses on VetScan (VetScan2, Abaxis, Union City, CA 94587, USA) and Olympus (Olympus AU640, Beckman Coulter, Brea, CA 92821, USA) analyzers within 2 hr of each other. Agreement between the VetScan and Olympus analyzers was investigated using Passing-Bablok regression analysis for aspartate aminotransferase, creatine kinase, glucose, calcium, phosphorus, total protein, albumin, globulin, potassium, and sodium. Agreement between the two analyzers was outside of acceptance limits and outside of clinical allowable error limits for all analytes as established by the American Society for Veterinary Clinical Pathology. The results of biochemical analyses of alligator snapping turtle plasma cannot be compared between VetScan and Olympus analyzers in a clinical setting. Comparison of biochemical analyses within analyzer units, however, may still be clinically useful. Future studies are warranted to investigate the precision of each analyzer for alligator snapping turtle plasma.
Related Concept Videos
Drug Dissolution: Requirements and Profile Comparison
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Evolutionary Relationships through Genome Comparisons
Comparison Between Electrical And Gravitational Forces
Since both are inverse square law forces, the distance gets canceled when the ratio of the two forces is considered. Instead, the ratio of the electrical and gravitational forces depends on...
Comparison between RL and RC circuits