Related Experiment Video
Updated: Jan 31, 2026

Sample Preparation for Probe Electrospray Ionization Mass Spectrometry
Published on: February 19, 2020
Direct quantification of inorganic iodine in seawater by mixed-mode liquid chromatography-electrospray
M Hernáiz-Izquierdo1, P Galindo-Iranzo1, M P García-Armada2
1Department of Atmospheric Chemistry and Climate, Institute of Physical Chemistry 'Rocasolano' (IQFR-CSIC), Serrano 119, 28006 Madrid, Spain.
Abstract:
Atmospheric iodine plays a relevant role in climate change. Bearing in mind that most of this iodine comes from the oceans, analytical methods capable of determining iodine in a challenging matrix as seawater are necessary. In this work, the first method capable of direct determination of total inorganic iodine in seawater at subnanomolar level based on mixed-mode liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) without any sample treatment is presented. Analytical characteristics of the developed method were studied in terms of linear range, limits of detection and quantification, precision, trueness, matrix effect, and robustness. The detection limit for iodide was as low as 0.16 nM, injecting 5 μL of seawater without any sample treatment and the working linear range of four orders of magnitude was wide enough to cover the broad concentration range observed in seawater samples. Average values for repeatability and intermediate precision were 4.1% and 8.1%, respectively. The suitability of the method was demonstrated through its application to the analysis of several types of samples, including seawater samples taken at different locations along the Spanish Mediterranean coast and some domestic iodized salts. According to the results obtained, the method developed is rapid, easy to apply and to be automated, avoids sample treatment and requires only few microliters of sample. Furthermore, it has a low detection limit and allows the quantification of inorganic iodine over a wide concentration range.
More Related Videos
07:25Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
Ionization Energy