A cellulose-based photoacoustic sensor to measure heparin concentration and activity in human blood samples
Ananthakrishnan Soundaram Jeevarathinam1, Navin Pai1, Kevin Huang1
1Department of NanoEngineering, University of California San Diego, La Jolla, CA 92093, United States.
Abstract:
Heparin is an indispensable drug in anticoagulation therapy but with a narrow therapeutic window, which dictates regular testing and dose adjustment. However, current monitoring tools have a long turnaround time or are operator intensive. In this work, we describe a cellulose-based photoacoustic sensor for heparin. The sensors have a turnaround time of 6 min for whole blood samples and 3 min for plasma samples regardless of heparin concentration. These sensors have a limit of detection of 0.28 U/ml heparin in human plasma and 0.29 U/ml in whole blood with a linear response (Pearson's r = 0.99) from 0 to 2 U/ml heparin in plasma and blood samples. The relative standard deviation was < 12.5% in plasma and < 17.5% in whole blood. This approach was validated with heparin-spiked whole human blood and had a linear correlation with the activated partial thromboplastin time (aPTT) (r = 0.99). We then studied 16 sets of clinical samples-these had a linear correlation with the activated clotting time (ACT) (Pearson's r = 0.86, P < 0.0001). The photoacoustic signal was also validated against the cumulative heparin dose (Pearson's r = 0.71, P < 0.0001). This approach could have applications in bed-side heparin assays for continuous heparin monitoring.
Related Concept Videos
Drug Concentrations: Measurements
Plasma...
Concentration Cells
Consider the following voltaic cell:
Measurement of Blood Pressure
Cellulose and Pectic Polysaccharides
As a cell matures, its cell wall specializes according to its type. For example, the...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...