Related Experiment Video
Updated: Jan 31, 2026

06:04
Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
1.1K
Erratum to: A real time surface electromyography signal driven prosthetic hand model using PID controlled DC motor
Retheep Raj1, Rejith Ramakrishnan1, Karingannikalam Subramanian Sivanandan1
1Department of Electrical Engineering, National Institute of Technology, Calicut, India.
Biomedical Engineering Letters
|January 4, 2019
Summary
This study corrects a previously published article DOI. The correction ensures accurate citation and referencing for scientific literature. This enhances data integrity in research.
Area of Science:
- Bibliometrics
- Scientific Publishing
- Research Integrity
Context:
- Correction of a published article DOI.
- Ensuring accurate referencing in scientific literature.
- Maintaining the integrity of research records.
Purpose:
- To provide the correct Digital Object Identifier (DOI) for a specific scientific article.
- To rectify an error in the article's metadata.
- To facilitate proper citation and retrieval of the research.
Summary:
- The article DOI: 10.1007/s13534-016-0240-4 has been corrected.
- This correction ensures that readers and indexing services can accurately locate the intended publication.
- Accurate DOIs are crucial for the discoverability and citation of scientific work.
Impact:
- Improved accuracy in scientific databases and literature searches.
- Enhanced reliability of citation tracking and impact analysis.
- Facilitation of seamless access to the corrected scientific content.
Related Concept Videos
PID Controller
704
Proportional-Integral-Derivative (PID) controllers are widely used in various control systems to enhance stability and performance. In a thermostat, it adjusts heating or cooling based on the temperature difference between the actual and desired levels. They are often used in automotive speed systems, effectively managing sudden speed changes while maintaining a constant speed under varying conditions. On the other hand, PI controllers, commonly employed in voltage regulation, enhance stability...
704
Cell-surface Signaling
54.4K
Hormones—or any molecule that binds to a receptor, known as a ligand—that are lipid-insoluble (water-soluble) are not able to diffuse across the cell membrane. In order to be able to affect a cell without entering it, these hormones bind to receptors on the cell membrane. When a first messenger, a hormone, binds to a receptor, a signal cascade is set off, causing second messengers, proteins inside the cell, to become activated, resulting in downstream effects.
54.4K
Hierarchy of Motor Control
6.2K
The hierarchy of motor control refers to the different levels of organization and processing involved in controlling movement in the body. These levels range from higher cortical areas involved in planning and decision-making to lower spinal cord reflexes that respond automatically to external stimuli.
6.2K
DC Generator
2.1K
An alternator converts mechanical energy into electrical energy that varies sinusoidally, resulting in AC current. Meanwhile, a DC generator converts mechanical energy into electrical energy, which are DC pulses with the same polarity. The construction of a DC generator is similar to that of an alternator, except that the pair of slip rings is replaced by a single split ring, also called a commutator. The commutator functions like a periodic rotary switch; it changes the contacts with the...
2.1K
Real Time RT-PCR
65.1K
Real-time reverse transcription-polymerase chain reaction, or Real-time RT-PCR, is an analytical tool used to determine the expression level of target genes. The method involves converting mRNA to complementary DNA with the help of an enzyme known as reverse transcriptase, followed by the PCR amplification of the cDNA. These two processes can be performed simultaneously in a single tube or separately as a two-step reaction.
The real-time quantification of the number of amplified products is...
The real-time quantification of the number of amplified products is...
65.1K
Basic Continuous Time Signals
688
Basic continuous-time signals include the unit step function, unit impulse function, and unit ramp function, collectively referred to as singularity functions. Singularity functions are characterized by discontinuities or discontinuous derivatives.
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
688

