Related Experiment Video
Updated: Jan 31, 2026

The Joint Effect of Social Comparison and Social Distance on Evaluation of Intertemporal Choice Outcomes in Event-related Potential Studies
Published on: August 25, 2023
Radiologic versus Endoscopic Placement of Gastrostomy Tube: Comparison of Indications and Outcomes at a Tertiary
Steven Clayton1, Christopher DeClue1, Trevor Lewis1
1From the University of South Carolina School of Medicine, Greenville, the Departments of Radiology and Internal Medicine, Morsani College of Medicine, University of South Florida, Tampa, the Department of Radiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts, and the Department of Internal Medicine, Ochsner Medical Center Jefferson, Louisiana.
Objectives:
Percutaneous gastrostomy tube placement is performed in patients requiring long-term enteral nutrition. Although both endoscopic and fluoroscopic techniques may be used, there are inherent risks and potential complications associated with both procedures that are not generally known to referring physicians. The purpose of this study was to compare and contrast indications for placement and procedurally related complications between fluoroscopic and endoscopic gastrostomy tubes techniques at a tertiary care facility.
Methods:
A retrospective cohort study was performed. All consecutive patients with either percutaneous endoscopic (PEG) or percutaneous radiologic (PRG) gastrostomy tube placement between October 2011 and January 2013 were eligible for inclusion. Basic demographic information, American Society of Anesthesiologists score, procedure indication, laboratory data, and use of anticoagulation were recorded. Both direct and indirect procedural complications were documented if they occurred 30 days after gastrostomy tube placement, and were classified and scored based on severity and need for further intervention.
Results:
A total of 297 patients met the inclusion criteria, 150 of whom had gastrostomy tubes placed fluoroscopically and 147 of whom had them placed endoscopically. There was no statistically significant difference in direct complications within the first 30 days (PEG 6.8% vs PRG 8%); however, the type of complication observed varied between the two groups. Although superficial wound infections and buried bumpers were more common in the PEG group, bleeding was more common in the PRG group.
Conclusions:
Placement of gastrostomy tubes either endoscopically or fluoroscopically is relatively safe with similar indications. Although the complication rate between the two groups was not significant, the types of procedural complications observed did vary.
Related Concept Videos
Indicators
Tertiary Healthcare System
Nomenclature of Secondary and Tertiary Amines
Enteral Nutrition II: Nasointestinal and Gastrostomy Feeding
Nasointestinal Feeding
Nasointestinal feeding involves placing a tube...
Lattice Centering and Coordination Number
Types of Unit Cells
Imagine taking a large number of identical...
Radiological Investigation I: X-ray and CT

