Determination of multiple chelator complexes in aqueous matrices using ultra-performance liquid
Sohag Miah1, Ismail M M Rahman2, Masashi Takemura1
1Graduate School of Natural Science and Technology, Kanazawa University, Kakuma, Kanazawa 920-1192, Japan.
Abstract:
The determination of aminopolycarboxylate chelators in environmental samples has remained an analytical challenge due to the structural similarities of these species and their minute concentrations in such matrices. Herein, we report a fast and sensitive technique for the determination of multiple chelator complexes in an aqueous matrix using ultra-performance liquid chromatography-quadrupole/time-of-flight mass spectrometry (UPLC-Q-TOF-MS). Eight chelators, including non-biodegradable (EDTA, EDTAOH, GEDTA, DPTAOH and DTPA) and biodegradable (EDDS, GLDA, and MGDA) variants were examined after complexation with CuII. The detection of these species using reverse-phase chromatography was compared with that achieved with hydrophilic interaction chromatography based on the corresponding peak resolution and retention time. The effect of varying the composition and pH of the mobile phase on the corresponding peak profiles and intensities for the chelator complexes was also evaluated. The CuII-derivatives of the chelators were individually detected under the optimized operating conditions. Relative to high-performance liquid chromatography equipped with a photodiode array detector, the developed UPLC-Q-TOF-MS technique provides rapid determination of chelator complexes in aqueous matrices with high sensitivity and superior peak resolution. The limit of detection ranged from 1.7-36 nmol L-1, and the limit of quantification ranged from 5.7-120 nmol L-1 for the eight chelator complexes in solution. The coefficients of determination (R2) were 0.962-0.999 for the chelators with an average relative uncertainty of 2.2%. The method was validated using a simulated mixed matrix and river water by standard addition (recovery: 83-100%).
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
09:09Semi-Quantitative Analysis of Peptidoglycan by Liquid Chromatography Mass Spectrometry and Bioinformatics
Published on: October 13, 2020
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....