Related Experiment Video
Updated: Jan 31, 2026

Designing CAD/CAM Surgical Guides for Maxillary Reconstruction Using an In-house Approach
Published on: August 24, 2018
Comparative evaluation of the mechanical properties of CAD/CAM dental blocks
Ruizhi Yin1, Yu-Kyoung Kim1, Yong-Seok Jang1
1Department of Dental Biomaterials, School of Dentistry, Chonbuk National University, 664-14, Duckjin-dong, Jeonju, 561-756, Republic of Korea.
Abstract:
This study compares the mechanical properties of commercially available CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) millable dental blocks including Vita Enamic, Lava Ultimate, and MAZIC Duro. All the discs were cut in dimension of 1.2 mm in thickness and 12 mm in diameter, ground up to #1200 Sic papers and polished. The biaxial flexure strength of the ceramic discs was measured after thermocycling treatment and the broken surfaces were observed using scanning electron microscopy (SEM). The discs were brushed using a toothbrush testing machine under a 150 g load. Surface roughness and morphology were determined after toothbrushing cycles. Finally, the friction and wear behavior of the materials against an opposing tooth were studied using a reciprocating pin-on-plate test configuration. The vertical loss of dental cusp was measured, and the surface image was examined using field emission scanning electron microscopy (FE-SEM). The biaxial flexural strength data were subjected to Weibull analysis. To compare the significance between the groups, all data were analyzed by one-way analysis (ANOVA). The biaxial flexural strength of the Lava Ultimate and MAZIC Duro materials is significantly higher than that of Vita Enamic. In addition, Lava Ultimate and MAZIC Duro exhibited significantly smoother surfaces than that of Vita Enamic after toothbrushing. Lava Ultimate and MAZIC Duro also showed less wear to the opposing tooth than that of Vita Enamic. In addition, Lava Ultimate possesses more suitable mechanical properties than the Vita Enamic and Mazic Duro for use in oral clinical prosthesis.
Related Concept Videos
C4 Pathway and CAM
C4 Pathway
The C4 pathway is used by plants such as...
Properties of Transition Metals
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Block Diagram Reduction
The first step in this process is the identification and relocation of a branch point. A branch point, where a...
Elements of Block Diagrams
A block diagram typically includes essential elements such as comparators, blocks, and feedback loops. Each of these elements...
Physical and Chemical Properties of Matter

