Related Experiment Video
Updated: Jan 31, 2026

09:21
Tuning the Acidity of Pt/ CNTs Catalysts for Hydrodeoxygenation of Diphenyl Ether
Published on: August 17, 2019
9.4K
To re-tune or not to re-tune: Comments on the flexible criterion
Alissa Melinger1, Rasha Abdel Rahman2
1Division of Psychology, University of Dundee, Dundee, UK.
Cognitive Neuropsychology
|January 8, 2019
Abstract
No abstract available in PubMed .
Related Concept Videos
Problem-Solving: Tuning of a Guitar String
1.1K
In the case of stringed instruments like the guitar, the elastic property that determines the speed of the sound produced is its linear mass density or the mass per unit length. This is simply called the linear density. If the string's linear density is constant along the string, then the linear density is simply the total mass divided by the total length.
The string's wave speed can be regulated by varying the linear density. Tension is the other property that determines the speed of...
The string's wave speed can be regulated by varying the linear density. Tension is the other property that determines the speed of...
1.1K
Routh-Hurwitz Criterion I
599
Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
599
Routh-Hurwitz Criterion II
1.1K
In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
1.1K
Pharmacokinetic Models: Comparison and Selection Criterion
359
Physiological and compartmental models are valuable tools used in studying biological systems. These models rely on differential equations to maintain mass balance within the system, ensuring an accurate representation of the dynamic processes at play.
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
359
Potential-Energy Criterion for Equilibrium
938
Potential energy or potential function plays an essential role in determining the stability of a mechanical system. If a system is subjected to both gravitational and elastic forces, the potential function of the system can be expressed as the algebraic sum of gravitational and elastic potential energy. If the system is in equilibrium and is displaced by a small amount, then the work done on the system equals the negative of the change in the system's potential energy from the initial to the...
938
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
1.3K
At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
1.3K

