Related Experiment Video
Updated: Jan 31, 2026

Integrated Photoacoustic Ophthalmoscopy and Spectral-domain Optical Coherence Tomography
Published on: January 15, 2013
Modified wavelength scanning interferometry for simultaneous tomography and topography of the cornea with Fourier
Susobhan Das1, Chih-Hao Liu1, Manmohan Singh1
1Department of Biomedical Engineering, University of Houston, Houston, TX 77004, USA.
Abstract:
Visual acuity is dependent on corneal shape and size. A minor variation in surface geometry can cause a deformation of corneal geometry, which affects its optical performance. In this work we demonstrate an algorithm for the simultaneous measurement of corneal tomography and topography with a traditional point-scanning Fourier domain optical coherence tomography (FD-OCT) system. A modified wavelength scanning interferometry (mWSI) algorithm enabled topographical evaluation of the surface with nanometer-scale resolution, which is superior to the micrometer-scale resolution of traditional OCT structural imaging. We validated the technique with an optically flat mirror, standard roughness gauges, and atomic force microscopy (AFM). The mirror results show nanometer-scale sensitivity (~3.5 nm), and the mWSI measurements were in good agreement (error ~5%) with the specifications of the roughness comparator and AFM, demonstrating the accuracy of the technique. Following validation, the measurements were made on pig corneas in situ at various artificially controlled intraocular pressures (IOP) and before and after cross-linking (CXL). The results show that the mean surface roughness increased by ~65% after removal of the epithelium in preparation for CXL but did not change as a function of IOP. The demonstrated method could be used for simultaneous measurement of tissue tomography with micrometer-precision and topography with nanometer-precision.
More Related Videos
06:19In Vivo Imaging of Cx3cr1gfp/gfp Reporter Mice with Spectral-domain Optical Coherence Tomography and Scanning Laser Ophthalmoscopy
Published on: November 11, 2017
12:22Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy oSLO and Optical Coherence Tomography OCT
Published on: August 4, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
The de Broglie Wavelength
Imaging Studies III: Computed Tomography
Methods of Obtaining Topography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET