Related Experiment Video
Updated: Jan 31, 2026

A Training and Testing System for Performing Vascular Reconstruction In Vitro
Published on: October 26, 2019
Effect of training on ultrasonography (US) BI-RADS features for radiology residents: a multicenter study comparing
Jung Hyun Yoon1, Hye Sun Lee2, You Me Kim3
1Department of Radiology, Research Institute of Radiological Science, Yonsei University, College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea.
Objectives:
To evaluate the effect of training radiology residents on breast ultrasonography (US) according to the Breast Imaging Reporting And Data System (BI-RADS) and the factors that influence the training effect.
Methods:
This multicenter, prospective study was approved by eight institutional review boards. From September 2013 to July 2014, 248 breast masses in 227 women were included for US image acquisition. Representative B-mode and video images of the breast masses were recorded, among which 54 cases were included in the education set and 66 in the test set. Sixty-one radiology residents scheduled for breast imaging training individually reviewed the test set, immediately before, 1 month after, and 6 months after training. Diagnostic performances and US descriptors of the residents were evaluated and compared against those of expert radiologists.
Results:
Agreements between residents and experienced radiologists showed improvement after training, while agreements between post-training and post-6-month training descriptors did not show significant differences (all p > 0.05, respectively). Sensitivity, negative predictive value (NPV), and AUC were significantly improved for residents post-training and post-6-month training (all p < 0.05), while approximating the performances of expert radiologists except for AUC (0.836, 0.840, and 0.908, respectively, p < 0.05). Low levels of pre-training AUC, total number of breast US examinations, and the number of sessions per week that residents were involved in were factors influencing the improvement of AUC.
Conclusion:
Training using education material dedicated for breast US imaging effectively improved the diagnostic performances of radiology residents and agreements with experienced radiologists on US BI-RADS features.
Key Points:
• Agreements on lesion descriptors between residents and experienced radiologists showed improvement after training, regardless of test point. • Sensitivity, NPV, and AUC were significantly improved for residents in post-training and post-6-month training (all p < 0.05). • Low levels of pre-training AUC, total number of breast US examinations, and the number of sessions per week that residents were involved in were factors influencing the improvement of AUC.
Related Concept Videos
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Radiological Investigation I: X-ray and CT
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...

