Analysis of thermolabile residual solvents in a spray dried dispersion using static headspace gas chromatography
Antonio Oliveira1, Stephen T Bambrick1, Laura Y Pfund1
1Analytical Commercialization Technology, Merck & Co., Inc., Rahway, New Jersey, USA.
Abstract:
In this study, we discuss the development of a static headspace gas chromatography method for the analysis of residual acetone as well as its enriched impurities including mesityl oxide and diacetone alcohol, in a spray dried dispersion. The major challenges include the instability of mesityl oxide and diacetone alcohol at high temperature and peak tailing of diacetone alcohol. It was found that the headspace oven temperature has to be controlled to 150°C or below to prevent degradation beyond an acceptable level (< 1%). The peak tailing of diacetone alcohol was attributed to the "Phase Soaking" effect due to excessive diluent, which may condense and temporarily modify the stationary phase. The peak shape of diacetone alcohol is dependent on the column loading capacity and the peak area of N-methyl pyrrolidone, the solvent that elutes after diacetone alcohol. The headspace oven temperature was set at 140°C, where the highest response ratio of diacetone alcohol/N-methyl pyrrolidone at 1.46 and thus the best sensitivity was obtained. The calculated quantitation limits were 1 ppm for acetone, 3 ppm for mesityl oxide and 31 ppm for diacetone alcohol. The method successfully passed validation criteria for specificity, linearity, accuracy, and precision.
More Related Videos
04:19Author Spotlight: An Improved Technique for Trimethylamine Detection in Animal-Derived Medicine by Headspace Gas Chromatography-Tandem Quadrupole Mass Spectrometry
Published on: March 10, 2023
09:03Assessment of Methane and Nitrous Oxide Fluxes from Paddy Field by Means of Static Closed Chambers Maintaining Plants Within Headspace
Published on: September 6, 2018
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Solvents
A...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...