Bilateral Angle Narrowing and Acute Myopia Induced by Indapamide: A Case Report
Ana Catarina Pedrosa1, Joana Rodrigues Araújo1, João Paulo Macedo1
1Department of Ophthalmology, Centro Hospitalar São João, Porto, Portugal.
Case Reports in Ophthalmological Medicine
|January 11, 2019
Summary
Indapamide medication can cause acute myopia and angle closure due to ciliochoroidal effusion. Prompt diagnosis and drug withdrawal lead to full recovery without lasting effects.
Area of Science:
- Ophthalmology
- Pharmacology
Background:
- Diuretic medications are commonly prescribed for hypertension.
- Sulfonamide-derived drugs, including indapamide, can have ocular side effects.
Observation:
- A case report details a 37-year-old man experiencing acute bilateral blurry vision after starting indapamide and amlodipine.
- Clinical examination revealed myopia, anterior chamber angle narrowing, and ciliochoroidal effusion.
Findings:
- Ultrasound biomicroscopy confirmed bilateral ciliochoroidal effusion and angle narrowing.
- Discontinuation of indapamide and management of intraocular pressure resulted in complete resolution of symptoms.
Implications:
- Indapamide can induce reversible acute myopia and angle closure glaucoma.
- Early recognition and withdrawal of indapamide are crucial for preventing permanent vision loss.
Related Concept Videos
Contact Angle
19.3K
When a solid is dipped inside a liquid, the liquid surface becomes curved near the contact. For some solid–liquid interfaces, the liquid is pulled up along the solid, while for others, the liquid surface is convex or depressed near the solid surface. This phenomenon can be explained using the concept of cohesive and adhesive forces.
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
19.3K
Distribution of Stresses in a Narrow Rectangular Beam
528
In studying beam stress distribution, examining an elemental section is essential. To determine the average shearing stress on this face, the calculated shear is divided by the surface area. Importantly, shearing stresses on the beam's transverse and horizontal planes mirror each other, indicating a consistent stress distribution along the upper region of the beam. Notably, shearing stresses are absent at the beam's upper and lower surfaces due to the absence of applied forces in these...
528
Open Angle Glaucoma: Treatment
994
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
994
Data Reporting and Recording
5.4K
Reporting and recording are crucial in data documentation. The timely, thorough, and accurate documentation of facts is essential when recording patient data. Failure to record findings during an assessment or interpretation of a problem will result in loss of information and make the patient document unreliable. The reader is left with general impressions if the information is not specific. A recording is documenting data of the individual's health information in a traceable, secure, and...
5.4K
Angle of Twist: Problem Solving
787
An electric motor applies a torque of 700 N·m to an aluminum shaft, triggering a stable rotation. Two pulleys, B and C, are subjected to torques of 300 N·m and 400 N·m, respectively. The modulus of rigidity is provided as 25 GPa. With the knowledge of the length and diameter of each segment, the twist angle between the two pulleys can be computed. First, a section cut is made between pulleys B and C, and the cut cross-section is analyzed using a free-body diagram. Given that the torque...
787
Types of Reports I: Hands-off Report
1.5K
A hand-off report, also known as a change-of-shift report, is a crucial nursing process that ensures the smooth transition of patient care responsibilities between nursing staff.
Following are the key components and categories of hand-off reports:
Purpose and Process:
Following are the key components and categories of hand-off reports:
Purpose and Process:
1.5K