Related Experiment Video
Updated: Jan 30, 2026

Modified Blood Collection from Tail Veins of Non-anesthetized Mice with a Vacuum Blood Collection System and Eyeglass Magnifier
Published on: February 2, 2019
Intraoperative Blood Loss during Induced Abortion: A Comparison of Anesthetics
Camille A Clare1, Gabrielle E Hatton2, Neela Shrestha3
1Department of Obstetrics and Gynecology, New York Medical College, Valhalla, New York, USA.
Objective:
To determine whether there is a difference in intraoperative bleeding with inhalational versus noninhalational anesthetic agents for patients undergoing suction dilatation and curettage for first-trimester induced abortion.
Methods:
This is an IRB-approved retrospective chart review of the electronic medical records of patients undergoing induced abortion at gestational ages between 5 0/7 and 14 0/7 weeks of pregnancy at the New York City Health + Hospitals/Metropolitan. The records of 138 patients who underwent suction dilatation and curettage for induced abortion between June 2012 and June 2014 were reviewed for an association between anesthetic technique and intraoperative hemorrhage. Twenty patients received inhalational anesthetic agents, while 118 received intravenous anesthetics. Blood loss was estimated by the operating gynecologists.
Results:
The mean intraoperative blood loss for inhalational anesthetics (113.6 ml) was significantly higher than with noninhalational agents (40.2 ml) (p=0.007). Age, body mass index, and gestational age were not statistically different between the groups; the number of methylergonovine doses at induced abortion trended higher with inhalation anesthetics.
Conclusions:
The difference in blood loss between the two types of anesthetic techniques was statistically significant. These findings may be important for patients with significant anemia or at an increased risk of bleeding, such as those with unrecognized coagulopathies.
Related Concept Videos
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
Local Anesthetics: Pharmacokinetics
Inhalational Anesthetics: Overview
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...

