Revisiting human cerebral blood flow responses to augmented blood pressure oscillations
J W Hamner1, Keita Ishibashi2, Can Ozan Tan1,3
1Cerebrovascular Research Laboratory, Spaulding Rehabilitation Hospital, Boston, MA, USA.
Key Points:
Cerebral autoregulation is most effective in buffering against pressure fluctuations slower than 0.03 Hz (∼30 s). This suggests that frequency bands for characterizing cerebral autoregulation should be redefined Low cross-spectral coherence below 0.03 Hz highlights the limitations of transfer function approaches Haemodynamic changes induced by lower body pressure could not fully explain the differences in autoregulation estimated from spontaneous vs. augmented fluctuations, and thus, observations of spontaneous fluctuations should not be relied on whenever possible.
Abstract:
There is currently little empirical basis for time scales that are considered to be most significant in cerebrovascular counter-regulation of changes in arterial pressure. Although it is well established that cerebral autoregulation behaves as a 'high-pass' filter, recommended frequency bands have been largely arbitrarily determined. To test effectiveness of cerebral autoregulation, we refined oscillatory lower body pressure (LBP) to augment resting pressure fluctuations below 0.1 Hz by a factor of two in 13 young male volunteers, and thoroughly characterized the time and frequency responses of cerebral autoregulation. We observed that despite a threefold increase in arterial pressure power <0.03 Hz with oscillatory LBP, there was no change in cerebral blood flow power, indicating near perfect counter-regulation. By contrast, in the range 0.03-0.10 Hz, both cerebral blood flow and arterial pressure power more than doubled. Our data demonstrate that cerebral autoregulation is most effective in buffering against pressure fluctuations slower than 0.03 Hz (∼30 s). This suggests that frequency bands of interest should be redefined and recording length should be increased considerably to account for this. Furthermore, low cross-spectral coherence below 0.03 Hz, even when pressure fluctuations were augmented, highlights the uncertainty in transfer function approaches and the need to either report precision or use non-linear approaches. Finally, haemodynamic changes induced by LBP could not fully explain the differences in autoregulation estimated from spontaneous vs. augmented fluctuations, and thus, observations of spontaneous fluctuations should not be relied on whenever possible.
Related Concept Videos
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Blood Flow
Measurement of Blood Pressure
Factors affecting Blood pressure
Physiological Factors:
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...