Ryunosuke Oikawa1, Goro Tajima1, Jun Yan2
1Department of Orthopaedic Surgery, Iwate Medical University, Iwate, Japan.
Background:
To clarify, with three-dimensional (3D) images, the morphological properties of the patellar tendon and both of its insertion sites.
Methods:
Thirty-two human cadaveric left knees were evaluated, and 3D computed tomography images were created. These images were used to analyse the morphology of both insertion sites of the patellar tendon, and the width, length and thickness of each region of the patellar tendon.
Results:
The insertion sites of the patellar tendon on the patellar and tibial sides were V-shaped and crescent-shaped, respectively, with the respective bony apexes located at 44.5 ± 2.2% (standard deviation) and 35.5 ± 2.8% of the tendon width from its medial edge. The proximal, central and distal widths of the patellar tendon were 29.9 ± 2.7 mm, 27.3 ± 2.5 mm and 25.0 ± 2.4 mm, respectively. The length of the patellar tendon was shortest at 40.6% ± 6.7% of the central width and gradually became longer toward both edges. The patellar tendon was thickest in the central portion of 40-75% and gradually became thinner toward both edges.
Conclusions:
The morphological properties of the patellar tendon and its insertion sites on both the patellar and tibial sides were consistent. These findings indicate that the characteristics of the bone-patellar tendon-bone graft markedly depend on the location from which it is harvested, and that these characteristics contribute to predicting the length, width and shapes of the bone plugs of the graft when performing bone-patellar tendon-bone surgery.
More Related Videos
11:49Using High Resolution Computed Tomography to Visualize the Three Dimensional Structure and Function of Plant Vasculature
Published on: April 5, 2013
08:50Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Conserved Binding Sites
Binding sites are often located in large pockets, and if their location on a protein’s surface is unknown, it can be predicted using various approaches. The energetic method computationally...
Conserved Binding Sites
Ligand Binding Sites
Protein-ligand interactions are quite specific; even though numerous potential ligands surround a cellular protein at any given time, only a particular ligand can bind to that protein. Moreover, a ligand binds only to a dedicated area on the surface of the protein, known as the...
Ligand Binding Sites