[Effect of Transcutaneous Acupoint Electrical Stimulation on Propofol Usage in Closed-loop Anes- thesia Delivery
Insights
Transcutaneous acupoint electrical stimulation (TEAS) reduced propofol usage and improved hemodynamic stability in pediatric patients undergoing surgery. TEAS also decreased stress and inflammatory responses, leading to better outcomes.
Area of Science:
- Anesthesiology
- Pain Management
- Integrative Medicine
Background:
- Pediatric anesthesia requires careful management of hemodynamics and stress response.
- Closed-loop anesthesia systems aim for precise drug delivery but may need adjunctive therapies.
- Transcutaneous acupoint electrical stimulation (TEAS) is a non-invasive technique with potential analgesic and anti-inflammatory effects.
Purpose of the Study:
- To evaluate the impact of TEAS on propofol consumption in a closed-loop anesthesia system.
- To assess the effects of TEAS on hemodynamic parameters in pediatric surgical patients.
- To investigate TEAS's influence on stress and inflammatory markers, and post-operative recovery.
Main Methods:
- A randomized controlled trial involving 60 pediatric patients undergoing tonsillectomy/adenoidectomy.
- Patients were assigned to either TEAS or a control group receiving standard anesthesia.
- Hemodynamic parameters, propofol dosage, stress hormones (epinephrine), inflammatory cytokines (IL-1, IL-6), and pain/delirium scales were monitored.
Main Results:
- The TEAS group showed significantly reduced mean arterial pressure and heart rate fluctuations.
- TEAS led to a significant decrease in total propofol dose and adjustment frequency.
- Reduced levels of epinephrine, IL-1, and IL-6 were observed in the TEAS group, alongside lower pain and emergence delirium scores.
Conclusions:
- TEAS effectively stabilizes pediatric hemodynamics during surgery.
- TEAS reduces the need for propofol in closed-loop anesthesia systems.
- TEAS mitigates stress and inflammatory responses, improving post-operative outcomes in children.
Abstract:
Objective To evaluate the effect of transcutaneous acupoint electrical stimulation (TEAS) on propofol usage in closed-loop anesthesia delivery system and pediatric hemodynamics. Methods Sixty children patients undergoing selective tonsillectomy and adenoidectomy surgeries were randomly allocated to the TEAS group (T) and the control group (C) , 30 in each group. Anesthesia maintenance in both groups was performed by propofol closed-loop anesthesia infusion system after induction of anesthesia. Patients in group T were treated with continuous TEAS (2/100 Hz sparsedense wave, 8 - 12 mA) at unilateral Hegu (L14) and Shenmen till the end of surgery. No TEAS was performed to patients in group C. Mean arterial pressure (MAP) and heart rate (HR) were recorded before anesthesia (TO), immediately after intubation ( T1) , 5 min after intubation (T2) , 10 min after intubation (T3) , 15 min after intubation (T4) , the time for intubation (T5) , respectively. The total dose of propofol, times for propofol dose adjustment, average target concentration, cases of patients with extra Fentanyl were recorded during anesthesia maintenance. Bispectral index (BIS) was recorded. Pediatric Anesthesia Emergence Delirium (PAED) scale and Modified Children's Hospital of Eastern Ontario Pain Scale (MCHEOPS) were assessed at T5, 5 min after extubation (T6) , 10 min after extubation (T7) , 15 min after extubation (T8), 30 min after extubation (T9) , respectively. Epinephrine (NE) was measured at TO, T1, T5, and T9, concentrations of IL-1 and IL-6 were measured at TO, T5, 24 h after surgery ( T10) , 48 h after surgery (T11), respectively. Results Compared with group C, MAP at T4 and T5 and HR at T1-T5 all de- creased, PAED scale and MCHEOPS decreased at T5-T9, NE concentrations were significantly reduced at T5 and T9, concentrations of IL-1 and IL-6 decreased at T5, T10, T1 1 in group T (P <0. 05, P <0. 01). Compared with group C, the total dose of propofol, times for propofol dose adjustment, average target concentration were reduced in group T during surgery (P <0. 05, P <0. 01). Twenty cases (67%) used propofol in group C and 9 cases (30% ) used propofol in group T during surgery, with statistical difference (P <0. 01). Changes of BIS was not statistically different between the two groups (P >0. 05). Conclusion TEAS could inhibit stress response and inflammatory response of children patients, stabilize their hemo- dynamics during surgery, thereby reducing propofol dose in closed-loop anesthesia delivery system.
Related Concept Videos
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Feedback Loops