Analysis of Dynamic Response of an MRI-Guided Magnetically-Actuated Steerable Catheter System
E Erdem Tuna1, Taoming Liu1, Russell C Jackson1
1Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH 44106, USA.
Abstract:
This paper presents a free-space open-loop dynamic response analysis for an MRI-guided magnetically-actuated steerable intra-vascular catheter system. The catheter tip is embedded with a set of current carrying micro-coils. The catheter is directly actuated via the magnetic torques generated on these coils by the magnetic field of the magnetic resonance imaging (MRI) scanner. The relationship between the input current commands and catheter tip deflection angle presents an inherent nonlinearity in the proposed catheter system. The system nonlinearity is analyzed by utilizing a pendulum model. The pendulum model is used to describe the system nonlinearity and to perform an approximate input-output linearization. Then, a black-box system identification approach is performed for frequency response analysis of the linearized dynamics. The optimal estimated model is reduced by observing the modes and considering the Nyquist frequency of the camera system that is used to track the catheter motion. The reduced model is experimentally validated with 3D open-loop Cartesian free-space trajectories. This study paves the way for effective and accurate free-space closed-loop control of the robotic catheter with real-time feedback from MRI guidance in subsequent research.
Related Concept Videos
Dynamic Equilibrium
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Photoreceptors and Plant Responses to Light
Magnetism
An individual magnetic pole cannot be isolated. No matter how small, every piece of a magnet contains a north pole and a south...
Responses to Gravity and Touch