Related Experiment Video
Updated: Jan 30, 2026

07:04
A Step Beyond BRET: Fluorescence by Unbound Excitation from Luminescence FUEL
Published on: May 23, 2014
12.0K
Simple calibrated nonlinear excitation regime two-line atomic fluorescence thermometry
Optics Letters
|January 16, 2019
Summary
A simplified two-dimensional (2D) thermometry method using nonlinear excitation regime two-line atomic fluorescence (NTLAF) reduces calibration complexity. This cost-effective approach enhances NTLAF
Area of Science:
- Combustion diagnostics
- Optical thermometry
- Laser spectroscopy
Background:
- Nonlinear excitation regime two-line atomic fluorescence (NTLAF) is a 2D thermometry technique for turbulent sooty flames.
- Current NTLAF methods face challenges due to complex calibration and expensive instrumentation.
Purpose of the Study:
- To develop a simplified and cost-effective NTLAF measurement approach.
- To reduce the number of system parameters requiring calibration in NTLAF.
Main Methods:
- A one-parameter NTLAF model was developed.
- Tunable diode laser absorption spectroscopy (TDLAS) was used for calibration.
- Path-averaged temperature from TDLAS calibrated a single system parameter.
Main Results:
- Instantaneous 2D thermometry data were acquired for a homemade burner.
- Measurement uncertainty was approximately 4.5%.
- Results showed deviations less than 50 K (typically within 20 K) from TDLAS and Rayleigh scattering measurements.
Conclusions:
- The proposed method offers a simplified NTLAF solution for noncontact, in-situ, high-resolution 2D temperature measurement.
- This approach is expected to improve NTLAF's compatibility in research and engineering applications.
Related Concept Videos
Atomic Fluorescence Spectroscopy
959
Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which...
959
Nonlinear Pharmacokinetics: Causes of Nonlinearity
725
Nonlinearity in drug pharmacokinetics is caused by various factors influencing how a drug is absorbed, distributed, metabolized, and excreted. Understanding these nonlinear processes is crucial for predicting drug behavior in the body and optimizing drug dosing regimens.
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
725
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
2.8K
Atomic spectroscopy is a vital tool in elemental analysis, both qualitatively and quantitatively. It can be broadly divided into optical spectroscopy, mass spectroscopy, and X-ray spectroscopy methods. The optical spectroscopic methods are atomic absorption spectroscopy (AAS), atomic emission spectroscopy (AES), and atomic fluorescence spectroscopy (AFS). The first step in all three methods is atomization, where the solid, liquid, or solution-phase samples are converted into gas-phase atoms and...
2.8K
The Atomic Theory of Matter
127.9K
The earliest recorded discussion of the basic structure of matter comes from ancient Greek philosophers. Leucippus and Democritus argued that all matter was composed of small, finite particles that they called atomos, meaning “indivisible.” Later, Aristotle and others came to the conclusion that matter consisted of various combinations of the four “elements” — fire, earth, air, and water — and could be infinitely divided. Interestingly, these philosophers...
127.9K
Glassware Calibration
1.4K
Accurate calibration of glassware, such as volumetric flasks, pipettes, and burettes, is essential to ensure accurate measurements in the analytical laboratory. Calibration helps maintain consistency across measurements and prevents errors arising from inaccurate volumes.
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
1.4K
Atomic Structure
209.3K
Overview
209.3K