Related Experiment Video
Updated: Jan 30, 2026

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
Published on: December 15, 2014
Utility of Diffusion-weighted Imaging to Decrease Unnecessary Biopsies Prompted by Breast MRI: A Trial of the
Habib Rahbar1, Zheng Zhang2, Thomas L Chenevert3
1University of Washington School of Medicine, Seattle, Washington. hrahbar@uw.edu.
Purpose:
Conventional breast MRI is highly sensitive for cancer detection but prompts some false positives. We performed a prospective, multicenter study to determine whether apparent diffusion coefficients (ADCs) from diffusion-weighted imaging (DWI) can decrease MRI false positives.Experimental Design: A total of 107 women with MRI-detected BI-RADS 3, 4, or 5 lesions were enrolled from March 2014 to April 2015. ADCs were measured both centrally and at participating sites. ROC analysis was employed to assess diagnostic performance of centrally measured ADCs and identify optimal ADC thresholds to reduce unnecessary biopsies. Lesion reference standard was based on either definitive biopsy result or at least 337 days of follow-up after the initial MRI procedure.
Results:
Of 107 women enrolled, 67 patients (median age 49, range 24-75 years) with 81 lesions with confirmed reference standard (28 malignant, 53 benign) and evaluable DWI were analyzed. Sixty-seven of 81 lesions were BI-RADS 4 (n = 63) or 5 (n = 4) and recommended for biopsy. Malignancies exhibited lower mean in centrally measured ADCs (mm2/s) than benign lesions [1.21 × 10-3 vs.1.47 × 10-3; P < 0.0001; area under ROC curve = 0.75; 95% confidence interval (CI) 0.65-0.84]. In centralized analysis, application of an ADC threshold (1.53 × 10-3 mm2/s) lowered the biopsy rate by 20.9% (14/67; 95% CI, 11.2%-31.2%) without affecting sensitivity. Application of a more conservative threshold (1.68 × 10-3 mm2/s) to site-measured ADCs reduced the biopsy rate by 26.2% (16/61) but missed three cancers.
Conclusions:
DWI can reclassify a substantial fraction of suspicious breast MRI findings as benign and thereby decrease unnecessary biopsies. ADC thresholds identified in this trial should be validated in future phase III studies.
More Related Videos
Related Concept Videos
Decreasing Function
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Diffusion
Diffusion
Decreased Body Temperature
Decreased pulse rate
There are specific risk factors that can elevate the likelihood of developing bradycardia. Advanced age is a significant factor, with...