Nanoparticle-based CT visualization of pulmonary vasculature for minimally-invasive thoracic surgery planning
Hsin-Pei Hu1, Harley Chan2, Hideki Ujiie1
1Division of Thoracic Surgery, Toronto General Hospital, University Health Network, Toronto, Ontario, Canada.
Purpose:
To evaluate CF800, a novel lipid-based liposomal nanoparticle that co-encapsulates indocyanine green (ICG) and iohexol, for CT imaging of pulmonary vasculature in minimally-invasive thoracic surgery planning.
Methods:
CF800 was intravenously administered to 7 healthy rabbits. In vivo CT imaging was performed 15 min post-injection, with a subset of animals imaged at 24h, 48h, and 72h post injection. Signal-to-background ratios (SBR) were calculated at the inferior vena cava and compared across time-points. A similar protocol was applied to 2 healthy pigs to evaluate the feasibility and efficacy in a large animal model. To evaluate the feasibility of clinical application, a survey was completed by 7 surgical trainees to assess pre- and post-injection CT images of rabbits and pigs. Responses on the discernibility of pulmonary vasculature sub-branches and comfort level to use the images for pre-operative planning were collected and analyzed.
Results:
CF800 injection improved visualization of pulmonary vessels in both rabbit and pig models. The SBR of rabbit pulmonary vasculature was significantly higher after CF800 injection (range 3.7-4.4) compared to pre-injection (range 3.3-3.8, n = 7; p<0.05). SBR remained significantly different up to 24 hours after injection (range 3.7-4.3, n = 4; p<0.05). Trainees' evaluation found the post-injection CT images had significantly higher discernibility at the second vessel branch generation in both rabbit and pig models. Trainees identified smaller vasculature branch generations in the post-injection images compared to the pre-treatment images in both rabbit (mean 6.7±1.8 vs 5.4±2.1; p<0.05) and pig (mean 6.7±1.8 vs 5.4±2.1; p<0.05). Trainees were significantly more comfortable using post-injection images for surgical planning compared to the pre-injection images (rabbit: 8.1±1.1 vs. 4.7±2.1; pig: 7.6±2.1 vs. 4.9±2.2; p<0.05).
Conclusion:
CF800 provides SBR and contrast enhancement of pulmonary vasculature which may assist in pre-surgical CT planning of minimally invasive thoracic surgery.
Related Concept Videos
Thoracic Aorta
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
The Thoracic Cage: Sternum
The sternum is the elongated bony structure on the anterior side of the thoracic cage. It consists of three parts: the manubrium, the body, and the xiphoid...
The Thoracic Cage: Ribs
Parts of a Typical Rib
A typical rib has a head, neck, and body. The posterior end of the rib is called the head, followed by a narrow neck. The head articulates primarily with the costal...
Planning Nursing Care I
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...