Related Experiment Video
Updated: Jan 30, 2026

Generation of Scalable, Metallic High-Aspect Ratio Nanocomposites in a Biological Liquid Medium
Published on: July 8, 2015
Flow of wormlike micellar solutions around microfluidic cylinders with high aspect ratio and low blockage ratio
Simon J Haward1, Naoyuki Kitajima, Kazumi Toda-Peters
1Micro/Bio/Nanofluidics Unit, Okinawa Institute of Science and Technology, Onna, Okinawa 904-0495, Japan. simon.haward@oist.jp.
Abstract:
We employ time-resolved flow velocimetry and birefringence imaging methods to study the flow of a well-characterized shear-banding wormlike micellar solution around a novel glass-fabricated microfluidic circular cylinder. In contrast with typical microfluidic cylinders, our geometry is characterized by a high aspect ratio α = H/W = 5 and a low blockage ratio β = 2r/W = 0.1, where H and W are the channel height and width, and the cylinder radius r = 20 μm. The small cylinder radius allows access up to very high Weissenberg numbers 1.9 ≤ Wi = λMU/r ≤ 3750 (where λM is the Maxwell relaxation time) while inertial effects remain entirely negligible (Reynolds number, Re < 10-4). At low Wi values, the flow remains steady and symmetric and a birefringent region (indicating micellar alignment and tensile stress) develops downstream of the cylinder. Above a critical value Wic ≈ 60 the flow transitions to a steady asymmetric state, characterized as a supercritical pitchfork bifurcation, in which the fluid takes a preferential path around one side of the cylinder. At a second critical value Wic2 ≈ 130, the flow becomes time-dependent, with a characteristic frequency f0 ≈ 1/λM. This initial transition to time dependence has characteristics of a subcritical Hopf bifurcation. Power spectra of the measured fluctuations become complex as Wi is increased further, showing a gradual slowing down of the dynamics and emergence of harmonics. A final transition at very high Wic3 corresponds to the re-emergence of a single peak in the power spectrum but at much higher frequency. We discuss this in terms of possible flow-induced breakage of micelles into shorter species with a faster relaxation time.
More Related Videos
Related Concept Videos
Poisson's Ratio
Odds Ratio
Hazard Ratio
For example, in a clinical trial...
The Ratio of X Chromosome to Autosomes
Normal male Drosophila has a ratio of one X chromosome to two sets of autosomes. In contrast, normal female...
Transformers with Off-Nominal Turns Ratios
Water Cement Ratio

