Related Experiment Video
Updated: Jan 30, 2026

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Intra-operative imaging in trauma surgery
Holger Keil1, Nils Beisemann1, Benedict Swartman1
1BG Trauma Center Ludwigshafen, Germany.
Abstract:
The reconstruction of anatomical joint surfaces, limb alignment and rotational orientation are crucial in the treatment of fractures in terms of preservation of function and range of motion. To assess reduction and implant position intra-operatively, mobile C-arms are mandatory to immediately and continuously control these parameters.Usually, these devices are operated by OR staff or radiology technicians and assessed by the surgeon who is performing the procedure. Moreover, due to special objectives in the intra-operative setting, the situation cannot be compared with standard radiological image acquisition. Thus, surgeons need to be trained and educated to ensure correct technical conduct and interpretation of radiographs.It is essential to know the standard views of the joints and long bones and how to position the patient and C-arm in order to acquire these views. Additionally, the operating field must remain sterile, and the radiation exposure of the patient and staff must be kept as low as possible.In some situations, especially when reconstructing complex joint fractures or spinal injuries, complete evaluation of critical aspects of the surgical results is limited in two-dimensional views and fluoroscopy. Intra-operative three-dimensional imaging using special C-arms offers a valuable opportunity to improve intra-operative assessment and thus patient outcome.In this article, common fracture situations in trauma surgery as well as special circumstances that the surgeon may encounter are addressed. Cite this article: EFORT Open Rev 2018;3:541-549. DOI: 10.1302/2058-5241.3.170074.
Related Concept Videos
Operational Amplifiers
Real Number Operations
Vector Operations
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.
Operant Conditioning
Reinforcement in operant conditioning can be positive or negative, both of which serve to increase the likelihood of a behavior. Positive...
Second Derivatives and Laplace Operator
Consider a scalar function. The curl of its...
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...

