Related Experiment Video
Updated: Jan 30, 2026

A Coregistered Ultrasound and Photoacoustic Imaging Protocol for the Transvaginal Imaging of Ovarian Lesions
Published on: March 3, 2023
Imaging Characteristics of Mismatch Lesions: An Angiographic and Intravascular Ultrasound Analysis of 1369 Coronary
Tan Quang Phan1,2, Lan Hieu Nguyen3,4, Lan Viet Nguyen3
11 Intervention Center, Quang Nam Central General Hospital, Quang Nam, Vietnam.
Objectives:
To evaluate the angiographic and intravascular ultrasound (IVUS) characteristics of coronary mismatch lesions.
Background:
Better understanding about the characteristics of mismatch lesions may help to achieve more accurate lesion assessment and, thereby, to improve the outcomes of percutaneous coronary intervention (PCI).
Methods:
Angiographic and IVUS data from 1369 lesions were analyzed. Mismatch lesion was defined as the difference between proximal and distal reference lumen diameters of ≥1.0 mm or ≥30% of the distal reference lumen diameter.
Results:
The incidence of mismatch lesions was 20.1% (275/1369). Compared to nonmismatch group, mismatch group had longer lesions (21.3 [6.4] mm vs 18.4 [6.4] mm, P < .001) with smaller minimum lumen diameter (0.87 [0.29] mm vs 1.10 [0.31] mm, P < .001) and more severe diameter stenosis (78.8% [9.2%] vs 66.3% [10.3%], P < .001). On IVUS, mismatch group had larger lumen area (18.7 [5.0] vs 15.8 [5.1] mm2, P < .001) but lower plaque burden at the proximal reference segment (41.0% [9.2%] vs 45.7% [9.9%], P < .001) and smaller lumen area (4.83 [1.89] vs 7.36 [2.89] mm, P < .001) but higher plaque burden at the distal reference segment (42.9% [10.4%] vs 41.4% [10.1%], P = .023). Multivariable logistic regression analysis showed that mismatch lesions were frequently accompanied by diffuse lesions (odds ratio [OR] = 2.50; 95% confidence interval [CI]: 1.83-3.40; P < .001), bifurcation lesions (OR = 5.83; 95% CI: 4.40-7.74; P < .001), and lesions with a low TIMI flow grade (OR = 1.70; 95% CI: 1.08-2.67; P = .022) or severe diameter stenosis (OR = 3.05; 95% CI: 2.10-4.43; P < .001).
Conclusions:
Mismatch lesions are quite common and characterized by greater lesion complexity compared with nonmismatch lesions. Further studies may be necessary to address the impact of this lesion type on the outcome of PCI.
More Related Videos
Related Concept Videos
Mismatch Repair
Mismatch Repair
The Mutator Protein Family Plays a Key Role in DNA Mismatch Repair
The human genome has more than 3 billion base pairs of DNA per cell. Prior to cell division, that vast amount of genetic...
Characteristics of Life
Coronary Circulation
Coronary circulation begins at the base of the aorta, where two main arteries arise—the left and right coronary arteries. These arteries encircle the heart in the coronary sulcus and supply the...
Characteristics of Fluids
Characteristics of BJT
For input characteristics, the base-emitter voltage is varied, maintaining a constant collector-emitter voltage. This setup reveals a Shockley-type dependence of the collector current on...